2020
DOI: 10.1016/j.sna.2020.112377
|View full text |Cite
|
Sign up to set email alerts
|

Amperometric determination of dopamine based on an interface platform comprising tetra-substituted Zn2+ phthalocyanine film layer with embedment of reduced graphene oxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…The AuNP modification process was easily promoted by a few potential cycles. The characterization showed both uniform distribu- TBABr/SDS•AuNPs/GO/GCE 0.02-1.0 0.01 [58] GCE-PPI-AuNPs 0.1-125 0.16 [59] AuNPs/1T-MoS 2 /GCE 0.2-80 0.16 [60] GCE/rGO−Zn(II)TPEBiPc 0.05-0.8 0.0016 [61] GCE-ERGO/polyCoTAPc 2.0-100 0.095 [62] Au-IPA-AmGQD-CoTCPhOPc 1.0-50 0.20 [63] CoTGPc/GCE 2-12 1.0 [64] The decrease in the sensitivity to DA concentration higher than 10 µmol/L can be ascribed to kinetic limitation, being related to irreversible adsorption of the DA molecules at electrode surface [65,66]. Indeed, the SPCE/p-NiTsPc/AuNP even in a solution in the absence of DA also showed DA peak oxidation (Figure S7) and the SERRS spectra also showed the DA vibration at 1483 cm −1 .…”
Section: Discussionmentioning
confidence: 99%
“…The AuNP modification process was easily promoted by a few potential cycles. The characterization showed both uniform distribu- TBABr/SDS•AuNPs/GO/GCE 0.02-1.0 0.01 [58] GCE-PPI-AuNPs 0.1-125 0.16 [59] AuNPs/1T-MoS 2 /GCE 0.2-80 0.16 [60] GCE/rGO−Zn(II)TPEBiPc 0.05-0.8 0.0016 [61] GCE-ERGO/polyCoTAPc 2.0-100 0.095 [62] Au-IPA-AmGQD-CoTCPhOPc 1.0-50 0.20 [63] CoTGPc/GCE 2-12 1.0 [64] The decrease in the sensitivity to DA concentration higher than 10 µmol/L can be ascribed to kinetic limitation, being related to irreversible adsorption of the DA molecules at electrode surface [65,66]. Indeed, the SPCE/p-NiTsPc/AuNP even in a solution in the absence of DA also showed DA peak oxidation (Figure S7) and the SERRS spectra also showed the DA vibration at 1483 cm −1 .…”
Section: Discussionmentioning
confidence: 99%
“…In these studies various symmetrical and unsymmetrical cobalt(II) and zinc(II) phthalocyanines were used (Figure 8). In the case of ZnPc, the very low limit of detection of 6 nM was obtained accompanied by linear range of 20 nM to 1 µM and sensitivity of 2.8784 µA µM −1 cm −2 [120].…”
Section: Catecholaminesmentioning
confidence: 96%
“…The gap was enough for the simultaneous determination of both substances in the same media [118]. Graphene quantum dots and reduced graphene oxide were also used as electron amplifiers in determination studies of dopamine, performed by Ndebele et al and Pari et al, respectively [119,120]. In these studies various symmetrical and unsymmetrical cobalt(II) and zinc(II) phthalocyanines were used (Figure 8).…”
Section: Catecholaminesmentioning
confidence: 99%
See 1 more Smart Citation