2018
DOI: 10.1016/j.ultras.2018.06.006
|View full text |Cite
|
Sign up to set email alerts
|

An adaptive beamforming method for ultrasound imaging based on the mean-to-standard-deviation factor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 46 publications
(13 citation statements)
references
References 48 publications
0
13
0
Order By: Relevance
“…( 1 ), CF of a perfectly coherent signal will be 1, and that of a perfectly incoherent signal will be 0. To further increase the difference between coherent and incoherent signals, the mean-to-standard-deviation (MSD) factor [ 14 ] and signal-to-noise-ratio (SNR) factor [ 15 ] were introduced. The CF value for a perfectly coherent signal is limited to 1 because CF is defined as the ratio of coherent energy to “total energy”.…”
Section: Adaptive Imaging Methodsmentioning
confidence: 99%
“…( 1 ), CF of a perfectly coherent signal will be 1, and that of a perfectly incoherent signal will be 0. To further increase the difference between coherent and incoherent signals, the mean-to-standard-deviation (MSD) factor [ 14 ] and signal-to-noise-ratio (SNR) factor [ 15 ] were introduced. The CF value for a perfectly coherent signal is limited to 1 because CF is defined as the ratio of coherent energy to “total energy”.…”
Section: Adaptive Imaging Methodsmentioning
confidence: 99%
“…Standard deviation (SD) is a statistical concept, which has been widely used in many fields. Such as in [33], standard deviation was used into industrial equipment to help process the signal of bubble detection in liquid sodium; in [34], standard deviation is used with delay multiply to form a new weighting factor, which is introduced to enhance the contrast of the reconstructed images in medical fields; in [35], based on eight-year-old dental trauma research data, standard deviation was utilized to help analyze the potential of laser Doppler flowmetry; the beam forming performance has a large impact on image quality in ultrasound imaging, to improve image resolution and contrast; in [36], a new adaptive weighting factor for ultrasound imaging called signal mean-to-standard-deviation factor (SMSF) was proposed, based on which researchers put forward an adaptive beam forming method for ultrasound imaging based on the mean-to-standard-deviation factor; in [37], standard deviation was adopted to help analyze when an individual should start social security.…”
Section: Standard Deviation Updating Amount (Sdua)mentioning
confidence: 99%
“…Cross coherence factor was devised by combing plane-and spherical-wave transmissions to reduce artifact caused by sidelobes in ultrafast ultrasound imaging [26]. A normalized autocorrelation factor was proposed for coherent planewave compounding to enhance lateral resolution and contrast [27]. Eigenspace-based coherence factor was presented to improve tissue harmonic imaging to achieve high resolution and good small target visibility at the same time [28].…”