An alternative cold cesium frequency standard: the continuous fountain

Abstract: Abstract-We report on the primary frequency standard now under construction at the Observatoire de Neuchâtel (ON). The design is based on a continuous fountain of lasercooled cesium atoms, which combines two advantages: the negligible contribution of collisions to the inaccuracy and the absence of stability degradation caused by aliasing effects encountered in pulsed operation. The design is reviewed with special emphasis on the specific features of a continuous fountain, namely the source, the microwave cavit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2000
2000
2018
2018

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 6 publications
0
13
0
Order By: Relevance
“…Similar behavior also may occur for flicker frequency noise, which is naturally observed up to a few Hertz in ultra-stable oscillators. Also, it is over a large Fourier frequency range, the natural behavior of microwave ultrastable oscillators [11] used as local oscillators in high performance atomic beam clocks [12].…”
Section: A Naturally "Not White" Phase Noisementioning
confidence: 99%
“…Similar behavior also may occur for flicker frequency noise, which is naturally observed up to a few Hertz in ultra-stable oscillators. Also, it is over a large Fourier frequency range, the natural behavior of microwave ultrastable oscillators [11] used as local oscillators in high performance atomic beam clocks [12].…”
Section: A Naturally "Not White" Phase Noisementioning
confidence: 99%
“…It continues as a joint effort between METAS and the Laboratoire Temps et Fréquence of the University of Neuchâtel (LTF-IMT). The design and construction of the continuous cesium fountain clock FOCS-1 was first described at EFTF1999 [16]. In 2003, this standard was transferred to METAS where its metrological evaluation is still in progress.…”
Section: Swiss Continuous Fountain Clocksmentioning
confidence: 99%
“…c) The continuous fountain [9][10][11] which allows one to reduce simultaneously intermodulation effects and collisional shifts by more than two orders of magnitude. This relaxes, by the same margin, the compromise faced in most pulsed fountains between high stability (but high collisional shift and uncertainty), and high accuracy (but moderate frequency stability), without resorting to a better oscillator than state-ofthe-art, space qualified, quartz oscillators.…”
Section: Short Time Stability and Reduction Of Intermodulation Effectsmentioning
confidence: 99%
“…1, together with its main operating characteristics. As described in detail in [9][10][11], the continuous beam is produced from a 3D molasses with three pairs of counter- propagating beams, orthogonal to each other, one horizontal and two at 45…”
Section: The Continuous Cold Cs Fountain Focs-1mentioning
confidence: 99%