2011
DOI: 10.1063/1.3634022
|View full text |Cite
|
Sign up to set email alerts
|

An analysis on transmission microwave frequency spectrum of cut-off probe

Abstract: Charge resolved electrostatic diagnostic of colliding copper laser plasma plumes Phys. Plasmas 18, 103104 (2011) Electron density measurement of inductively coupled plasmas by terahertz time-domain spectroscopy (THz-TDS) J. Appl. Phys. 110, 073303 (2011) A synchronized emissive probe for time-resolved plasma potential measurements of pulsed discharges Rev. Sci. Instrum. 82, 093505 (2011) Electrical time resolved metrology of dust particles growing in low pressure cold plasmas Phys. Plasmas 18, 093701 (2011) Ad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
30
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 36 publications
(31 citation statements)
references
References 9 publications
1
30
0
Order By: Relevance
“…A novel method, usable under various conditions, which is known as the wave cutoff method using a transmittance of wave was developed by Kim et al [15][16][17] The cutoff probe, using the physical phenomenon of the plasma resonance created by the plasma inductance and capacitance, 18 is believed to be one of the most promising diagnostic tools due to its numerous advantages. For instance, the probe system is very simple and robust and the calculation of the electron density (n e ) from the measured cutoff frequency (…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A novel method, usable under various conditions, which is known as the wave cutoff method using a transmittance of wave was developed by Kim et al [15][16][17] The cutoff probe, using the physical phenomenon of the plasma resonance created by the plasma inductance and capacitance, 18 is believed to be one of the most promising diagnostic tools due to its numerous advantages. For instance, the probe system is very simple and robust and the calculation of the electron density (n e ) from the measured cutoff frequency (…”
Section: Introductionmentioning
confidence: 99%
“…2 The theoretical error bar for the electron density measurement which originates from the choosing of the minimum value point as the cutoff point is known to be small. 18,19 The cutoff probe is more convenient than the hairpin probe for its use of lower frequency. 20 advantages, the cutoff probe is widely applied in measurements of the electron density in industrial plasma.…”
Section: Introductionmentioning
confidence: 99%
“…The magnitude and phase of the transmission spectrum provide informative peaks and slopes characterizing the plasma-sheath. When we see the phase of transmission spectrum (strictly speaking phase difference spectrum between current and voltage), the sign of the phase changes with frequency in series, plus, minus and plus [7,10]. This sign changes are originated from the fact that the property of the cutoff probe changes with frequency in series, capacitor, inductor, and capacitor as noted in the previous studies [7,9,10].…”
Section: Resultsmentioning
confidence: 71%
“…The FDTD simulation is known to be accurate solver of Maxwell's equations with realistic assumptions. It reproduces the experimentally obtained spectra of various microwave probes as well as the cutoff probe [7,[11][12][13][14][15][16]. The input parameters in the FDTD simulation are the material characteristic of the plasma density and collision frequency in the Drude model.…”
Section: Methodsmentioning
confidence: 71%
See 1 more Smart Citation