Abstract:Experimental tests were performed on a model shadow shield thermal protection system to examine the effect of certain configuration variables,, The experimental results were used to verify the ability of an analytical program to predict the shadow f> shield performance including the shield-support interaction. In o general, the analysis (assuming diffuse surfaces) agreed well with ' the experimental support temperature profiles. The agreement for the shield profiles was not as good. The results demonstrated (1… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.