2018
DOI: 10.1002/mp.12991
|View full text |Cite
|
Sign up to set email alerts
|

An analytical dose‐averaged LET calculation algorithm considering the off‐axis LET enhancement by secondary protons for spot‐scanning proton therapy

Abstract: We confirmed that the dual-LET-kernel model well reproduced the MCS, not only in the homogeneous phantom but also in complex patient geometries. The accuracy of the LET was largely improved from the single-LET-kernel model, especially at the lateral penumbra. The model is expected to be useful, especially for proper recognition of the risk of side effects when the target is next to critical organs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
32
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 21 publications
(32 citation statements)
references
References 37 publications
0
32
0
Order By: Relevance
“…This causes the 1D method to overestimate LET d in the high dose region while underestimating LET d in low dose regions (see Figs. 2(b1)-2(c2) (with energies of 140.8 and 70.2 MeV) of Hirayama et al 25 to Fig. In contrast, our hybrid 3D method can simultaneously calculate accurate LET d distributions in both high-dose and low-dose regions.…”
Section: Discussionmentioning
confidence: 92%
See 3 more Smart Citations
“…This causes the 1D method to overestimate LET d in the high dose region while underestimating LET d in low dose regions (see Figs. 2(b1)-2(c2) (with energies of 140.8 and 70.2 MeV) of Hirayama et al 25 to Fig. In contrast, our hybrid 3D method can simultaneously calculate accurate LET d distributions in both high-dose and low-dose regions.…”
Section: Discussionmentioning
confidence: 92%
“…Due to the strong correlation between LET and RBE, several groups have developed LET-guided optimization techniques 4,8,13,[19][20][21][22][23][24][25] that shift high LET toward the target volume and away from the OARs to reduce toxicity. The recently published TG-256 report 15 also suggested assessing the potential clinical consequences associated with variable RBE models and recommended LET-guided optimization in treatment planning systems (TPSs).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…There are two approaches to calculating LET distributions: Monte Carlo (MC) simulations and analytical methods . Generally speaking, MC is considered more accurate than analytical methods, but MC involves much longer calculation times and most institutions to date rely on analytical methods.…”
Section: Introductionmentioning
confidence: 99%