2022
DOI: 10.1016/j.saa.2021.120262
|View full text |Cite
|
Sign up to set email alerts
|

An eco-friendly modified methodology for the resolution of binary pharmaceutical mixtures based on self-deconvolution of the UV spectrophotometric spectra in the Fourier domain: Application of Fourier self-deconvolution in UV spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 13 publications
0
11
0
Order By: Relevance
“…2 ), and XIP was resolved and quantified by FSD method at 261.0 nm. The FSD approach tends to reduce excessively overlapping spectra, enhancing the resolution of overlapping spectra by eliminating the broadening impact caused by the spectrophotometer convolution [ 17 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…2 ), and XIP was resolved and quantified by FSD method at 261.0 nm. The FSD approach tends to reduce excessively overlapping spectra, enhancing the resolution of overlapping spectra by eliminating the broadening impact caused by the spectrophotometer convolution [ 17 ].…”
Section: Resultsmentioning
confidence: 99%
“…The physical convolution brought on by instrumental distortions to spectrum signals was eliminated by the currently employed technique. What gives the current methodology its resolving capacity is the evolution of major spectral zones with zero-crossing or no contribution points between the spectra of mixed components [ 17 ]. Reversing the physical convoluting, distorting impacts from the spectrophotometer performed to the recorded spectrum is the underlying idea behind FSD [ 21 ].…”
Section: Resultsmentioning
confidence: 99%
“…Accuracy was studied by performing recovery experiments. [42][43][44][45][46] The accuracy of the proposed HPLC method was established at 80%, 100% and 120% level. The placebo was added to the standard solution and % recovery was calculated.…”
Section: Accuracymentioning
confidence: 99%
“…The precision of the proposed HPLC method was studied by performing repeatability study and intraday precision for both the drugs. [43][44][45][46] The repeatability study was performed by injecting 40 mcg/ml of Celecoxib and 4 mcg/ml for Amlodipine (n=6). The intraday precision was studied by injecting 20, 30 and 40 mcg/ml for Celecoxib and 2, 3 and 4 µg/mL for Amlodipine (n=3) and % RSD was calculated.…”
Section: Precisionmentioning
confidence: 99%
See 1 more Smart Citation