2017
DOI: 10.1007/s00216-017-0403-x
|View full text |Cite
|
Sign up to set email alerts
|

An efficient direct competitive nano-ELISA for residual BSA determination in vaccines

Abstract: A simple, fast, and highly sensitive direct competitive enzyme-linked immunosorbent assay (ELISA) based on bovine serum albumin (BSA) antigen labeled amine-terminated silicon dioxide (SiO-NH-BSA) nanoparticles was developed to determine residual BSA in vaccines. As nano-ELISA using nanomaterials with a very high surface-to-volume ratio has emerged as a promising strategy, SiO-NH-BSA nanoparticles were prepared in this study by the coupling of BSA to SiO nanoparticles modified with amidogen, followed by the qua… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 34 publications
0
7
0
Order By: Relevance
“…Horseradish peroxidase-hydrogen peroxide-3,3′5,5′-tetramethylbenzidine (HRP-H2O2-TMB) is a coloring system that is commonly used in enzyme-linked immune-absorbent assay ELISA [20,21]. TMB is oxidized to blue in the presence of HRP and H2O2.…”
Section: Introductionmentioning
confidence: 99%
“…Horseradish peroxidase-hydrogen peroxide-3,3′5,5′-tetramethylbenzidine (HRP-H2O2-TMB) is a coloring system that is commonly used in enzyme-linked immune-absorbent assay ELISA [20,21]. TMB is oxidized to blue in the presence of HRP and H2O2.…”
Section: Introductionmentioning
confidence: 99%
“…Some of the binding sites on HSA binding to free naproxen were measured, while others binding to HRP-naproxen. After centrifugal separation of excessive HRP, the catalytic color reactions were investigated on an HRP/TMB/H 2 O 2 system [33,34,35] by the HRP-naproxen/nano-SiO 2 -HSA composite. The free naproxen to be measured and HRP-naproxen added were competitively bound to HSA, thus the higher content of naproxen in the sample, the less HRP-naproxen binding to HSA, resulting in a weaker color of the substrate solution.…”
Section: Resultsmentioning
confidence: 99%
“…The HSA immobilized nano-SiO 2 nanoparticles (SiO 2 -HSA) were prepared following our similar procedures reported previously [33,34,35]. Briefly, SiO 2 nanoparticles (nano-SiO 2 ) were firstly prepared by the hydrolysis of TEOS according to the typical Stöber process.…”
Section: Methodsmentioning
confidence: 99%
“…Under these conditions, the recoveries of 11 compounds were GA 93.56 ± 1.39%, PC 91.71 ± 1.02%, VA 93.61 ± 1.52%, SA 94.75 ± 0.79%, FA 92.26 ± 1.52%, Que 88.29 ± 1.32%, C 91.13 ± 0.72%, EC 95.76 ± 1.16%, GCG 93.35 ± 0.92% ECG 92.67 ± 1.08% and EGCG 92.71 ± 0.84%. The consistency between the predicted values and experimental values was assessed by Bland-Altman analysis [ 25 ]. Using 95% as the confidence interval, the limits of agreement for measurement difference were [−0.0029, 0.0421].…”
Section: Resultsmentioning
confidence: 99%