An electrocardiogram signal compression techniques: a comprehensive review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(17 citation statements)
references
References 96 publications
0
17
0
Order By: Relevance
“…The modified folded undecimator based ECG detector is implemented and simulated using Xilinx System Generator (XSG) and tested with standard MIT-BIH Arrhythmia database 22 . MIT-BIH Arrhythmia database consists of 48 recordings sampled at 360 Hz and 11 bits resolution with a range of 10 mV [23][24][25] . The modified architecture is tested with signals of MIT-BIH short time database (10-s), medium database (1-min) and full length database (1-h) 22,26 .The performance of both conventional and modified ECG detectors are evaluated using sensitivity S e , Positive prediction P + and Detection Error Rate(DER) 9,23,27 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The modified folded undecimator based ECG detector is implemented and simulated using Xilinx System Generator (XSG) and tested with standard MIT-BIH Arrhythmia database 22 . MIT-BIH Arrhythmia database consists of 48 recordings sampled at 360 Hz and 11 bits resolution with a range of 10 mV [23][24][25] . The modified architecture is tested with signals of MIT-BIH short time database (10-s), medium database (1-min) and full length database (1-h) 22,26 .The performance of both conventional and modified ECG detectors are evaluated using sensitivity S e , Positive prediction P + and Detection Error Rate(DER) 9,23,27 .…”
Section: Resultsmentioning
confidence: 99%
“…MIT-BIH Arrhythmia database consists of 48 recordings sampled at 360 Hz and 11 bits resolution with a range of 10 mV 23 – 25 . The modified architecture is tested with signals of MIT-BIH short time database (10-s), medium database (1-min) and full length database (1-h) 22 , 26 .The performance of both conventional and modified ECG detectors are evaluated using sensitivity S e , Positive prediction P + and Detection Error Rate(DER) 9 , 23 , 27 . A beat by beat comparison is performed for signals present in the database and calculated using ( 18 )–( 19 ).…”
Section: Resultsmentioning
confidence: 99%
“…DDC with HE [ 28 ] encodes the pre-processed signal directly without any transformation. HE was performed directly on the data [ 33 ].…”
Section: Methodsmentioning
confidence: 99%
“…SVD is used to factorize the signal into three smaller sets of values [ 27 ], which preserves features for digital biomarker development. BD-WT is widely used in ECG data compression [ 14 , 16 , 23 , 28 ]. DCT-DOST is a more recent method that has shown to be very robust for ECG signal compression [ 25 ].…”
Section: Introductionmentioning
confidence: 99%
“…More complex reviews on compression methods can be found in studies by Jalaleddine 40 (1990), Manikandan 12 (2014), Kale 16 (2016), Rajankar 41 (2018), Tiwari 42 (2019). Summary of quality assessment of ECG signals after compression are in reviews by Dandapat 43 (2015) and Nemcova 15 (2018).…”
Section: Introductionmentioning
confidence: 99%