2020
DOI: 10.3390/bios11010001
|View full text |Cite
|
Sign up to set email alerts
|

An Electrochemical Aptasensor for Pb2+ Detection Based on Metal–Organic-Framework-Derived Hybrid Carbon

Abstract: A new double-shelled carbon nanocages material was synthesized and developed an aptasensor for determining Pb2+ in aqueous solution. Herein, nanoporous carbon materials derived from core–shell zeolitic imidazolate frameworks (ZIFs) demonstrated excellent electrochemical activity, stability, and high specificity surface area, consequently resulting in the strong binding with aptamers. The aptamer strands would be induced to form G-quadruplex structure when Pb2+ was introduced. Under optimal conditions, the apta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(5 citation statements)
references
References 55 publications
0
5
0
Order By: Relevance
“…Guanine rich oligonucleotides favor detection of Pb 2+ by forming a G-quadruplex structure with high specificity. This structure exhibits good stability even with interference from other metal ions [56].…”
Section: Pb 2+ Detectionmentioning
confidence: 97%
“…Guanine rich oligonucleotides favor detection of Pb 2+ by forming a G-quadruplex structure with high specificity. This structure exhibits good stability even with interference from other metal ions [56].…”
Section: Pb 2+ Detectionmentioning
confidence: 97%
“…The current increases with Pb 2+ concentration. The findings demonstrated a solid linear association between the Pb 2+ concentration and the range of 0.1 to 10 ugL −1 with a detection limit of 0.096 ugL −1 [ 65 ].…”
Section: Electrochemical Biosensor Detection Of Heavy Metalsmentioning
confidence: 99%
“…( b ) Presentation diagram of the preparation process for the aptasensor and Pb 2+ detection, SEM image and TEM image of ZIF-8@ZIF-67 [ 65 ]. Reprinted with permission [ 65 ]. Copyright 2020, Biosensors.…”
Section: Figures and Schemementioning
confidence: 99%
“…The aptamers were able to recognize Pb 2+ and measure the cyclic voltammetry. Furthermore, this aptasensor exhibited reproducibility and practicability; however, high concentrations of Ag + , K +, and NH 4+ caused interferences in the performances suggesting that further research should be performed in order to avoid such effects [ 35 ].…”
Section: Recent Advances In Aptamer-based Biosensorsmentioning
confidence: 99%