2019
DOI: 10.1016/j.jchromb.2019.04.028
|View full text |Cite
|
Sign up to set email alerts
|

An FPSE-HPLC-PDA method for rapid determination of solar UV filters in human whole blood, plasma and urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 56 publications
(25 citation statements)
references
References 20 publications
0
24
0
1
Order By: Relevance
“…The developed method provides satisfactory limit of detection 0.15 ng/µL. Locatelli in 2019 [41] proposed a fabric phase sorptive extraction based method prior to high-performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) for the simultaneous extraction and analysis of six benzophenone derivative UV filters, including benzophenone (BZ), 5-benzoyl-4-hydroxy-methoxybenzenesulfonic acid (BP-4), bis(4-hydroxyphenyl)methanone (4-DHB), bis(2,4-dihydroxyphenyl)methanone (BP-2), (2,4-dihydroxybenzophenone) (BP-1), and 2,2 -dihydroxy-4-methoxybenzophenone (DHMB) in human whole blood, plasma, and urine samples. The limit of quantification was found to be 0.1 µg/mL.…”
Section: Applicationsmentioning
confidence: 93%
“…The developed method provides satisfactory limit of detection 0.15 ng/µL. Locatelli in 2019 [41] proposed a fabric phase sorptive extraction based method prior to high-performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) for the simultaneous extraction and analysis of six benzophenone derivative UV filters, including benzophenone (BZ), 5-benzoyl-4-hydroxy-methoxybenzenesulfonic acid (BP-4), bis(4-hydroxyphenyl)methanone (4-DHB), bis(2,4-dihydroxyphenyl)methanone (BP-2), (2,4-dihydroxybenzophenone) (BP-1), and 2,2 -dihydroxy-4-methoxybenzophenone (DHMB) in human whole blood, plasma, and urine samples. The limit of quantification was found to be 0.1 µg/mL.…”
Section: Applicationsmentioning
confidence: 93%
“…[13], [21], [37], [51] Remote UVC light sources are used in public environments is safe and economical to reduce environmentally transmitted diseases. [38], [39], [40], [44], [47], [48] [19], [24], [33], [36] They performed detection methods in ultraviolet light in fields such as bioanalytics or pharmacokinetics, diagnostics in diseases.…”
Section: Temas Y Funcionalidad Referencesmentioning
confidence: 99%
“…In this work, following our previous work on whole blood and non-conventional matrices [16][17][18][19][20][21] was validated a new, fast, high-throughput, and reproducible GC-FID assay for the evaluation of the ethanol concentration in blood and vitreous humor. The purpose was to highlight that the new method is a valid and validated alternative to other procedures, confirming the correlation between these different specimens, as reported in literature [22][23][24][25], that allow estimating blood alcohol concentrations when blood is unavailable or contaminated or in cases where blood analysis cannot be carried out.…”
Section: Introductionmentioning
confidence: 99%