An Improved Approach for Accurate and Efficient Measurement of Common Carotid Artery Intima-Media Thickness in Ultrasound Images

Abstract: The intima-media thickness (IMT) of common carotid artery (CCA) can serve as an important indicator for the assessment of cardiovascular diseases (CVDs). In this paper an improved approach for automatic IMT measurement with low complexity and high accuracy is presented. 100 ultrasound images from 100 patients were tested with the proposed approach. The ground truth (GT) of the IMT was manually measured for six times and averaged, while the automatic segmented (AS) IMT was computed by the algorithm proposed in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 27 publications
0
7
0
2
Order By: Relevance
“…Once, the coordinates of the arterial wall boundary are recorded, its distance is measured using mean absolute difference metrics [20]. It is one of the most used methods for IMT and LD measurement if the same numbers of coordinate in both the contours are available.…”
Section: Imt and Ld Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…Once, the coordinates of the arterial wall boundary are recorded, its distance is measured using mean absolute difference metrics [20]. It is one of the most used methods for IMT and LD measurement if the same numbers of coordinate in both the contours are available.…”
Section: Imt and Ld Measurementmentioning
confidence: 99%
“…However, IMT estimation underperforms with some existing method [18,21,22]. We have measured LD of the CCA with MAD metrics [20]. The coordinates of the LI interface in far and nearwall has already extracted in 'LI and MA detection in far wall' sub-section and 'LII detection in near-wall' subsection respectively.…”
Section: Imt and Ld Measurementmentioning
confidence: 99%
“…A variety of existing algorithms can be incorporated into the device to obtain these measurements [15]. However, we propose a novel lumen-diameterbased anomaly detection algorithm (Fig.…”
Section: System Operationmentioning
confidence: 99%
“…The earliest method for IMT measurement was reported in 1986 [6]. Since then, many approaches and techniques have been reported in numerous studies [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22]. Additionally, almost all of these methods consist of two steps: (i) finding the region of interest (ROI) and estimating the initial boundaries (LII, MAI) and (ii) tracing the real boundaries.…”
Section: Introductionmentioning
confidence: 99%
“…Molinari et al [17] developed a fully automated method, called completely automated multi-resolution edge snapper (CAMES), that can find the CCA's value based on a combination of scalespace and statistical classifications in a multi-resolutional framework. Other methods, such as the watershed transform in the work of Menchon-Lara et al [20] and the method of template-based matching in the research of Li et al [21], were applied to extract the ROI. For the second step, many dissimilar approaches, such as those based on dynamic programming [7,14], active contours [9, 11-13, 18, 19], neural networks [20], and random field models [22], have been developed.…”
Section: Introductionmentioning
confidence: 99%