2016
DOI: 10.1016/j.snb.2016.06.078
|View full text |Cite
|
Sign up to set email alerts
|

An improved non-enzymatic hydrogen peroxide sensor based on europium functionalized inorganic hybrid material—Evaluation of optical and electrochemical properties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 58 publications
0
3
0
Order By: Relevance
“…Hydrogen peroxide sensors are relevant since the use of H 2 O 2 is of great importance in clinical and environmental studies as well as in mining, pharmaceutical, textile, and food manufacturing industries . For this reason, much attention has been given to the development of chemical, biochemical, and electrochemical , sensors for this analyte since they provide high sensitivity, excellent selectivity, a rapid response, and good reliability.…”
Section: Part 2 Applications That Take Advantage Of Modifications At ...mentioning
confidence: 99%
“…Hydrogen peroxide sensors are relevant since the use of H 2 O 2 is of great importance in clinical and environmental studies as well as in mining, pharmaceutical, textile, and food manufacturing industries . For this reason, much attention has been given to the development of chemical, biochemical, and electrochemical , sensors for this analyte since they provide high sensitivity, excellent selectivity, a rapid response, and good reliability.…”
Section: Part 2 Applications That Take Advantage Of Modifications At ...mentioning
confidence: 99%
“…Rare earth elements, due to their unique properties of 4f-5d electronic orbitals, have attracted the attention of scientists who are considering the development of nanocomposites based on these elements for electrode modification, which would have the same function as noble metal nanocomposites [28,29]. Certain REEs are already used for electrochemical research [30,31]. Europium has been considered a significant lanthanide element with greater redox reaction behavior through its variable oxidation states [32].…”
Section: Introductionmentioning
confidence: 99%
“…Many fluorescence probes showed strong affinity to react with H 2 O 2 and they were applied for H 2 O 2 detection in living cells [11,12,13,14,15]. However, these probes are commonly used by adding them to aqueous samples, and they cannot be reused [16,17,18,19,20]. Scientists are looking for new ways to convert fluorescence probes into optical sensors for reuse.…”
Section: Introductionmentioning
confidence: 99%