2006
DOI: 10.1201/9781420011838
|View full text |Cite
|
Sign up to set email alerts
|

An Introduction to Biomedical Optics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
104
1
4

Year Published

2010
2010
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 85 publications
(109 citation statements)
references
References 0 publications
0
104
1
4
Order By: Relevance
“…5c). This indicates that the depth penetration, as defined as a combination of both absorption and scattering, and measured as the surviving intensity of light, is similar in both cases (4). Fitting an exponential function to these curves gives a characteristic depth penetration of 1.04 AE 0.04 and 0.97 AE 0.03 mm for ICG and SWNT respectively.…”
Section: Resultsmentioning
confidence: 95%
See 1 more Smart Citation
“…5c). This indicates that the depth penetration, as defined as a combination of both absorption and scattering, and measured as the surviving intensity of light, is similar in both cases (4). Fitting an exponential function to these curves gives a characteristic depth penetration of 1.04 AE 0.04 and 0.97 AE 0.03 mm for ICG and SWNT respectively.…”
Section: Resultsmentioning
confidence: 95%
“…The benefit of higher resolution unfortunately comes at the cost of limited tissue penetration depth (4). Absorption by biological tissue and water is one factor that leads to attenuation of signal proportional to the depth of the feature of interest.…”
mentioning
confidence: 99%
“…When they are modulated out of phase, existing system noise or any other background absorption would be significantly suppressed from the system, and the difference between the two signals would be amplified. Therefore, differential PA signals from those two wavelengths allow one to Figure 1 Human Hb molar extinction coefficient spectrum with arrows indicating two wavelengths of interest for the WM-DPAS system; re-plotted from data obtained from [18].…”
Section: Biomedical Applicationsmentioning
confidence: 99%
“…The principle of OCT will be described next. Optical coherence tomography is a non-destructive and noncontact imaging modality that reconstructs depthresolved images of biological tissue based on local optical property distribution in two-and three-dimensional layout (Gibson et al, 2006;Choma, 2004;Jiang et al, 1998;Jiang et al, 1997;Najarian, 2005;Splinter, 2006), whereas the physical reconstruction process can be found in signal processing literature (Najarian & Splinter, 2005;Splinter & Hooper, 2006).…”
Section: Optical Coherent Imagingmentioning
confidence: 99%