2003
DOI: 10.1088/0029-5515/43/11/021
|View full text |Cite
|
Sign up to set email alerts
|

An ITER-relevant evacuated waveguide transmission system for the JET-EP ECRH project

Abstract: An over-moded evacuated waveguide line was chosen for use in the transmission system for the proposed JET-enhanced performance project (JET-EP) electron cyclotron resonance heating (ECRH) system. A comparison between the quasi-optical, atmospheric waveguide and evacuated waveguide systems was performed for the project with a strong emphasis placed on the technical and financial aspects. The evacuated waveguide line was chosen as the optimal system in light of the above criteria. The system includes six lines o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2007
2007
2008
2008

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…As mentioned above a diamond window [32] is located just outside the closure plate providing a primary tritium barrier between the launcher and the transmission line [33]. An isolation valve is placed on the plasma side of the diamond window so that the window can be repaired in situ without affecting the torus pressure [34]. Both the isolation valve and the diamond window fit into the launcher back end as shown in the inset of figure 11, which results in an extremely congested launcher entrance complicating maintenance access to either the isolation valves or the diamond windows.…”
Section: The Mm-wave Systemmentioning
confidence: 99%
“…As mentioned above a diamond window [32] is located just outside the closure plate providing a primary tritium barrier between the launcher and the transmission line [33]. An isolation valve is placed on the plasma side of the diamond window so that the window can be repaired in situ without affecting the torus pressure [34]. Both the isolation valve and the diamond window fit into the launcher back end as shown in the inset of figure 11, which results in an extremely congested launcher entrance complicating maintenance access to either the isolation valves or the diamond windows.…”
Section: The Mm-wave Systemmentioning
confidence: 99%
“…An alternative containment scheme is proposed in figure 8(b), which inverts the ordering of the window-valve at the primary barrier and introduces a second diamond window in the TL. Reversing the window-valve provides additional protection to the diamond window (the valve is closed when the EC system is not used) and provides in situ maintenance and leak testing without affecting the torus pressure similarly to the configuration proposed for JET-EP [25]. The additional window ensures that the MOU, gyrotron and the majority of the TL remain clean, simplifying the maintenance procedures of these components.…”
Section: Transmission Line To Launchersmentioning
confidence: 99%
“…The new ITER fusion nuclear reactor [92] is likely to utilise mitred bends in the waveguides. These waveguides, which are 72 m in length, but only 63.5 mm diameter, include nine mitred bends.…”
Section: Review Of Literature On Mitresmentioning
confidence: 99%