DOI: 10.1016/j.rser.2014.10.070
|View full text |Cite
|
Sign up to set email alerts
|

An overview on thermal and fluid flow characteristics in a plain plate finned and un-finned tube banks heat exchanger

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
24
0
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 91 publications
(27 citation statements)
references
References 139 publications
1
24
0
2
Order By: Relevance
“…There are a significant number of experimental studies [2][3][4][5][6][7][8][9][10][11][12] that investigate heat transfer characteristics and pressure drop in tube banks and a greater number of numerical studies [13][14][15][16][17][18][19][20][21][22][23][24] on those subjects as well. Although most of the aforementioned studies focus on heat transfer and pressure drop, more detailed studies investigate entropy generation as well as energy and exergy efficiencies of tube banks and HRSG systems.…”
Section: Literature Reviewmentioning
confidence: 99%
“…There are a significant number of experimental studies [2][3][4][5][6][7][8][9][10][11][12] that investigate heat transfer characteristics and pressure drop in tube banks and a greater number of numerical studies [13][14][15][16][17][18][19][20][21][22][23][24] on those subjects as well. Although most of the aforementioned studies focus on heat transfer and pressure drop, more detailed studies investigate entropy generation as well as energy and exergy efficiencies of tube banks and HRSG systems.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The Grimison experimental model for staggered or aligned tubes arrangements was developed in 1937 to calculate the average Nusselt number for a tube bundle by the following correlation [14], [15], [16]:…”
Section: ❖ Grimison Modelmentioning
confidence: 99%
“…The Zhukauskas model, published in 1972, was proposed as a result of experimental studies with an accuracy of ±15% [15], [17]. This model is governed by the following correlation [12], [15], [19], [20]:…”
Section: ❖ Zhukauskas Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…Owing to its ease of processing and installment, as well as low cost and proven technique [6,7], finned tube heat exchanger has been widely applied in fields of air conditioner [8][9][10][11] and power plant [12][13][14]. In traditional air conditioning system, the finned tube heat exchanger can only exchange sensible heat.…”
Section: Introductionmentioning
confidence: 99%