2012
DOI: 10.1016/j.ijhydene.2012.01.163
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and simulation of a hydrogen based electric system to improve power quality in distributed grids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 16 publications
0
7
0
1
Order By: Relevance
“…The average voltage across the capacitor must be maintained at a constant value. The causes of its variation are mainly the losses in the switches (in conduction and commutation), in the decoupling inductances Lf and the injection of the fundamental currents during the transient regimes [10][11][12][13]. In steady state, the source must provide active power equal to the power demanded by the load.…”
Section: Voltage Control Of DC Busmentioning
confidence: 99%
“…The average voltage across the capacitor must be maintained at a constant value. The causes of its variation are mainly the losses in the switches (in conduction and commutation), in the decoupling inductances Lf and the injection of the fundamental currents during the transient regimes [10][11][12][13]. In steady state, the source must provide active power equal to the power demanded by the load.…”
Section: Voltage Control Of DC Busmentioning
confidence: 99%
“…A fuel cell is an electrochemical device that converts chemical energy into electrical energy, by means of a chemical reaction in an electrolyte, generating water [10], [11] and heat as waste [12]. There are many types of fuel cells, differentiated mainly by the electrolyte used.…”
Section: The Comprehensive Theoretical Basis 21 Modeling and Characteristics Of Fc Stackmentioning
confidence: 99%
“…The mathematical model is developed in the toolbox "SimPowerSystems" of Matlab/ Simulink [14]. The PEMFC is preferred operated in the Ohmic region because of the better efficiency [15]. One disadvantage of the fuel cells is that the voltage is not constant but varies with the current taken from the cell.…”
Section: The Comprehensive Theoretical Basis 21 Modeling and Characteristics Of Fc Stackmentioning
confidence: 99%
“…The power factor and/or harmonics can be compensated for by modifying the inverter control strategy to acquire an active power filter. The seven-level MFI-CM in [173] is used to interface the electrolyzer or fuel cell with the utility grid as shown in Fig. 20.…”
Section: Multilevel Current Source Mfi (Mfi-cm)mentioning
confidence: 99%