Analysis of a flexible surface-coil-type resonator for magnetic resonance measurements

Abstract: A flexible surface-coil-type resonator using triaxial cable Rev.This paper presents a method for analyzing the sensitivity of a flexible surface-coil-type resonator (FSCR). It first describes the configuration and the operation principle of the FSCR and then a method for estimating relative sensitivity of the FSCR. In this estimation, the quality factor and the filling factor of the FSCR are formulated because the strength of electron spin resonance (ESR) signals is proportional to the product of these factors… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

1997
1997
2013
2013

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(19 citation statements)
references
References 15 publications
0
19
0
Order By: Relevance
“…la). This coil diameter is a theoretically and experimentally optimized value for EPR measurements at ah EPR frequency of 700 MHz [6]. The second coil, 10 mm wide, was constructed from a copper plate 0.5 mm thick (Fig.…”
Section: Scrsmentioning
confidence: 99%
See 1 more Smart Citation
“…la). This coil diameter is a theoretically and experimentally optimized value for EPR measurements at ah EPR frequency of 700 MHz [6]. The second coil, 10 mm wide, was constructed from a copper plate 0.5 mm thick (Fig.…”
Section: Scrsmentioning
confidence: 99%
“…A surface-coil-type resonator (SCR) is one of the EPR resonators that operate in the ultrahigh-frequency (UHF) band [5][6][7]. It is composed of a singleturn col!…”
Section: Introductionmentioning
confidence: 99%
“…[16][17][18] The SCR consisted of a single-turn coil (f = 10 mm) and transmission lines that were formed by the flexible coaxial cables. 15 The SCR was connected to the microwave circuit through a three-stub tuner and driven at a resonant frequency of approximately 720 MHz.…”
Section: A Radiofrequency Esr Spectrometermentioning
confidence: 99%
“…been shown to have good signal responses to the nitroxyl radicals, such as 4-hydroxy-2,2,6,6-tetramethylpiperidine 1-oxyl (TEMPOL), which is used as a redox probe. A surface-coil-type resonator (SCR) that is mechanically flexible was first developed by Hirata et al 15 We previously fabricated three types of SCRs and performed temporal ESR measurements at several sites in rats (liver, kidney, stomach, rectum, vein, and skin) following the injection of TEMPOL. 16 Results of our studies have suggested that the SCR method may be useful in the direct evaluation of the in vivo redox status in localized organs.…”
Section: Introductionmentioning
confidence: 99%
“…12 Hirata et al developed an improved external loop resonator with an automatic matching control system for in vivo ESR. 13 This loop resonator system allows one to measure an ESR signal while compensating perturbations due to movement of the subject animal. This modified system appears to be potentially valuable in applying in vivo ESR to human subjects, where the need to reduce noise from movements is also a major concern.…”
Section: Introduction: History Of In Vivo Epr or Esrmentioning
confidence: 99%