2016 International Symposium on Antennas and Propagation (APSYM) 2016
DOI: 10.1109/apsym.2016.7929146
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of a single shorted rectangular microstrip antenna for 50Ωmicrostrip line feed

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 6 publications
1
6
0
Order By: Relevance
“…Further, Table III loaded HMSAs is at least 20 dB better than that of a single shorting post HMSA for both the angular ranges (configuration A and B). This is a notable improvement in the value of CTCR as compared to that obtained from the inset fed HMSA as listed in Table I, as well as RMSA as reported in [10][11].…”
Section: Pair Of Shorting Post-50ω-ms-line Fed Hmsamentioning
confidence: 55%
See 1 more Smart Citation
“…Further, Table III loaded HMSAs is at least 20 dB better than that of a single shorting post HMSA for both the angular ranges (configuration A and B). This is a notable improvement in the value of CTCR as compared to that obtained from the inset fed HMSA as listed in Table I, as well as RMSA as reported in [10][11].…”
Section: Pair Of Shorting Post-50ω-ms-line Fed Hmsamentioning
confidence: 55%
“…HMSAs with the pair of shorting posts gives more than 20 dB suppression of cross-polarization level in boresight direction in comparison with that of a single shorted HMSA, in H-plane. This suppression is 10 dB higher as compared to that reported for the RMSA with a pair of shorting posts [10], [11]. Simulation has been performed using IE3D software [18].…”
Section: A 50ω Microstrip Line Fed Shorted Hexagonal Microstrip Antenmentioning
confidence: 89%
“…Compact and shorted configurations of rectangular, circular and triangular antennas with the shorting post technique have been reported in [2,4]. Besides realizing compactness, the shorting technique has also been used to obtain dual-frequency response [5], tunability [9], impedance matching [10][11][12][14][15][16], etc. Recently, various configurations of compact and broadband MSAs have been reported using shorting techniques [6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…A rectangular MSA (RMSA) provides flexibility for directly feeding through 50 Ω-MS-line along the non-radiating edges [2,3,11,16]. However, there is no flexibility to feed Circular MSA (CMSA) directly with 50 Ω-MS-line as there are no non-radiating edges all along the periphery [2,3,11].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation