Analysis of dermal composite conditions using collagen absorption characteristics in the THz range

Abstract: Abstract:The absorption characteristics of the dermis were reviewed in the terahertz range from 0.2 to 2 THz. The absorption magnitude of the dermis was higher than that of the epidermis model owing to the inclusion of collagen fibers. The heat denaturation of the collagen and the decrease of water content in the dermis caused a decrease in the absorption magnitude of the dermis. We verified that the absorption magnitude of collagen sheets at 1 THz similarly decreased by nearly 43% upon the heat treatment at a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…Collagen absorbs THz radiation, thus providing data about the tissue structure and enrolled processes. 101 Far-infrared spectroscopy was able to detect the collagen amount and its spectral shape changes after the addition of a salt solution. 102 TPS allowed for detection of different salt concentrations in the collagen layers and drug absorption in the skin.…”
Section: Thz Instrumentationmentioning
confidence: 99%
“…Collagen absorbs THz radiation, thus providing data about the tissue structure and enrolled processes. 101 Far-infrared spectroscopy was able to detect the collagen amount and its spectral shape changes after the addition of a salt solution. 102 TPS allowed for detection of different salt concentrations in the collagen layers and drug absorption in the skin.…”
Section: Thz Instrumentationmentioning
confidence: 99%
“…The simulation used the real (ε ) and imaginary (ε ) parts of the complex permittivity to specify the tissue dielectric properties. The ε' and ε" for the skin components are based on available published data [35][36][37][38][39][40][41][42][43][44]. The lack of direct data necessitated use of data for tissue components rather than whole tissues and applying mixing formulae based on water content [37,45,46] to determine dielectric values.…”
Section: Transmission Absorption and Thermal Characteristicsmentioning
confidence: 99%
“…The dielectric values, expressed as the real ( ϵ ′) and imaginary ( ϵ ″) parts of the complex permittivity, refractive index, and absorption coefficient, are set out in Table . The values are derived from data from Huang et al [], Jördens et al [], Png et al [], Sy et al [], Sim et al [,], Guseva et al [], Yamaguchi et al [], Hernandez‐Cardoso et al [], Hübers et al [], and Mizuno et al [], and the analysis of mixing formulae is from Jördens et al [] and Ney and Abdulhalim []. A comprehensive outline of the derivation is provided in the supplementary material (S2).…”
Section: Introductionmentioning
confidence: 99%
“…The stratum corneum has only 15% water content, and thus ϵ ″ remains high in the model. The values are derived from Huang et al [], Jördens et al [], Png et al [], Sy et al [], Sim et al [,], Guseva et al [], Yamaguchi et al [], Hernandez‐Cardoso et al [], Hübers et al [] and Mizuno et al [].…”