2014
DOI: 10.1016/j.amjcard.2014.07.048
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Different Device-Based Intrathoracic Impedance Vectors for Detection of Heart Failure Events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring Study)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0
3

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 52 publications
(31 citation statements)
references
References 19 publications
0
28
0
3
Order By: Relevance
“…This is also consistent with clinical practice where no single sign or symptom is interpreted in isolation but in the context of all available clinical data. This may partly explain why single sensors that target individual sign or symptom, such as impedance for volume status, and minute ventilation and activity for exertion dyspnoea have had modest performance . A Heart Sound sensor provides an opportunity to target multiple aspects of HF pathophysiology given the differential haemodynamic correlates of various HS amplitude and timing parameters.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This is also consistent with clinical practice where no single sign or symptom is interpreted in isolation but in the context of all available clinical data. This may partly explain why single sensors that target individual sign or symptom, such as impedance for volume status, and minute ventilation and activity for exertion dyspnoea have had modest performance . A Heart Sound sensor provides an opportunity to target multiple aspects of HF pathophysiology given the differential haemodynamic correlates of various HS amplitude and timing parameters.…”
Section: Discussionmentioning
confidence: 99%
“…This may partly explain why single sensors that target individual sign or symptom, such as impedance for volume status, and minute ventilation and activity for exertion dyspnoea have had modest performance. [30][31][32] A Heart Sound sensor provides an opportunity to target multiple aspects of HF pathophysiology given the differential haemodynamic correlates of various HS amplitude and timing parameters. The HS measured using an existing accelerometer within the implanted cardiac devices may aid in building a more holistic picture of patients clinical status without additional hardware or surgery.…”
Section: Implications For Chronic Monitoring Of Heart Failure Patientsmentioning
confidence: 99%
“…But this point is not supported by the recent published data. A multicenter prospective study aiming to optimize vector configuration of ITI monitoring algorithm of St. Jude devices resulted in low sensitivity for HF event prediction . The LIMIT‐CHF trial, which included more than 50% of the patients with St. Jude Medical ICD or CRT‐D devices with CorVue™ algorithm, failed to show the benefit of empirical diuretic therapy guided by ITI monitor alerts in chronic HF patients to prevent HF hospitalization and unplanned HF care .…”
Section: Discussionmentioning
confidence: 99%
“…In addition, external and implanted impedance measurement devices have been proposed as potential future tools in the assessment of pulmonary congestion . These devices have been investigated as assessment and monitoring devices for pulmonary oedema, although with inconsistent findings with respect to their diagnostic and prognostic utility in HF populations …”
Section: Discussionmentioning
confidence: 99%