Analysis of geological materials by inductively coupled plasma mass spectrometry with sample introduction by electrothermal vaporisation. Part 1. Determination of molybdenum and tungsten

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
10
0

Year Published

1988
1988
2014
2014

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 71 publications
(11 citation statements)
references
References 0 publications
1
10
0
Order By: Relevance
“…Several approaches have been used to overcome this, including use of different chemical modifiers, 38,39 addition of reactive gases, [38][39][40][41][42] use of graphite rod direct sample insertion (DSI) devices, 43 a carbon cup, 44 and vaporization from a filament of W, Re or Ta or from platforms coated with these elements. 45,46 The aim of this study was to develop an ETV-ICP-MS method for the determination of Th, U and Pu in environmental and clinical samples.…”
mentioning
confidence: 99%
“…Several approaches have been used to overcome this, including use of different chemical modifiers, 38,39 addition of reactive gases, [38][39][40][41][42] use of graphite rod direct sample insertion (DSI) devices, 43 a carbon cup, 44 and vaporization from a filament of W, Re or Ta or from platforms coated with these elements. 45,46 The aim of this study was to develop an ETV-ICP-MS method for the determination of Th, U and Pu in environmental and clinical samples.…”
mentioning
confidence: 99%
“…This nding is also consistent with the improved metal release observed in electrothermal vaporization ovens in the presence of Freon. 32 It is worth noting that the formed HF caused signicantly increased Si background resulting in spectral interference of the Ni 221.648 nm emission line. Up to now no visible degeneration of the combustion tube was observed.…”
Section: Analyte Response For Different Solventsmentioning
confidence: 99%
“…For liquid sample introduction, coupling of the ETV to the ICP-MS offers several advantages over nebulization (1)(2)(3), including (i) the amount of solution needed for the analysis is very small (5-10 ml), (ii) the significantly improved transport efficiency gives rise to lower detection limits, and (iii) by the use of appropriate heating programs and/or matrix modifiers both spectral and nonspectral interferences can be reduced. Studies reporting on the exploration (4)(5)(6)(7)(8)(9) and exploitation (10)(11)(12)(13)(14)(15) of these characteristics can be widely found in the literature.…”
Section: Introductionmentioning
confidence: 99%