Analysis of testosterone in human urine using molecularly imprinted solid‐phase extraction and corona discharge ion mobility spectrometry

Abstract: Analysis of testosterone was accomplished using corona discharge ion mobility spectrometry. Molecular imprinted polymer was used for the extraction and pre-concentration of testosterone. Analytical parameters including precision, dynamic range and detection limit were obtained. The linear dynamic range was from 10 to 250 ng/mL and the limit of detection was 0.9 ng/mL. The proposed method was used for analysis of testosterone in urine samples. A urine sample from a 3-year-old girl was used as the blank. The RSD… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 31 publications
0
7
0
1
Order By: Relevance
“…Meanwhile, the operative error is hard to be avoided. In order to simplify the pretreatment procedure and improve the method sensitivity, some new techniques such as molecular imprinted polymer solid phase extraction (SPE) [25,26], solid phase microextraction (SPME) [27], stir bar microextraction (SBME) [28] and online SPE [29,30], have also been applied to determine AAS in diverse biological samples.…”
Section: Introductionmentioning
confidence: 99%
“…Meanwhile, the operative error is hard to be avoided. In order to simplify the pretreatment procedure and improve the method sensitivity, some new techniques such as molecular imprinted polymer solid phase extraction (SPE) [25,26], solid phase microextraction (SPME) [27], stir bar microextraction (SBME) [28] and online SPE [29,30], have also been applied to determine AAS in diverse biological samples.…”
Section: Introductionmentioning
confidence: 99%
“…It is a potentially useful technique for determining some chemical compounds such as explosives, pesticides, narcotics, and various environmental pollutants . The advantages of IMS are portability, high sensitivity, low detection limit, and low cost .…”
Section: Introductionmentioning
confidence: 99%
“…16 In the clinical eld, molecularly imprinted solid phase extraction and corona discharge ion mobility spectrometry were used to determine testosterone in urine. 17 However, there are no previous reports in which SPE was used to preconcentrate analytes in environmental samples and to analyze its extract by HS-IMS.…”
Section: Introductionmentioning
confidence: 99%