18th IEEE International Symposium on Power Line Communications and Its Applications 2014
DOI: 10.1109/isplc.2014.6812356
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the devolo's 500 kHz G3-PLC access technology based on smart grid field trials

Abstract: In the smart grid, the G3-PLC solution is in direct competition with other IP-based communications technologies such as GPRS or DSL. In this paper, we present the devolo's 500 kHz G3-PLC access technology and it's analysis based on smart grid field trials in Germany. The focus of the analysis in this paper is concentrated on the following parameters: The influencing factor of near and far transmission throughput, the influence of a repeater on the throughput, and the influence of different UDP packet size on t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
4
1

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…The same test procedure is done with 6 concurrent PAN clients. However Carrier Sense Multiple Access with Collision Avoidance (CSMA/CA) mechanism is typically used for medium access control on the shared medium by the PLC modems [9], no significant increase in connection time compared to single modem tests is measured. Thus, reconnection ability could be successfully demonstrated.…”
Section: Figure 7 Exemplary Results Of a Plc Reconnection Testsmentioning
confidence: 99%
“…The same test procedure is done with 6 concurrent PAN clients. However Carrier Sense Multiple Access with Collision Avoidance (CSMA/CA) mechanism is typically used for medium access control on the shared medium by the PLC modems [9], no significant increase in connection time compared to single modem tests is measured. Thus, reconnection ability could be successfully demonstrated.…”
Section: Figure 7 Exemplary Results Of a Plc Reconnection Testsmentioning
confidence: 99%
“…An important aspect is the standardization of these technologies. The most recognized standards for NPLC are ITU-T G.hnem [ 10 ], IEEE 1901.2 [ 11 ], PRIME [ 12 , 13 ] and G3-PLC [ 14 , 15 ]. The BPLC systems are supported by fewer standards, e.g., IEEE P1901 [ 16 , 17 ].…”
Section: State Of the Artmentioning
confidence: 99%
“…Authors in [60] focus mainly on PLC communication with a maximum distance of 200 m, including 21 nodes field tested in Germany. The topic of usage repeater is discussed with regard to the quality of communication channels, round-trip time and throughput.…”
Section: Real Measurements-related Workmentioning
confidence: 99%