2018
DOI: 10.1002/dta.2540
|View full text |Cite
|
Sign up to set email alerts
|

Analytical considerations for (un)‐targeted metabolomic studies with special focus on forensic applications

Abstract: Over the past few years, the interest in metabolomics has increased in various fields including forensic toxicology. Forensic analysis typically requires a high degree of accuracy, which is often a problem in metabolomics applications. We aimed for a systematic evaluation of different analytical considerations of a metabolomics workflow allowing a targeted approach within an untargeted setup. Samples with 69 metabolites from different chemical classes were qualitatively and quantitatively analyzed on a high re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
27
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 23 publications
(28 citation statements)
references
References 48 publications
1
27
0
Order By: Relevance
“…Urine samples of the experimental nights after placebo and GHB intake of 19 participants (sample of one participant was unavailable) were thawed at room temperature and vortexed for 20 seconds. Forty μL of the IS mix (adenosine ribose‐D 1 15 μmol/L, arginine‐ 13 C 6 300 μmol/L, caffeine 3‐methyl‐ 13 C 200 μmol/L, carnitine trimethyl‐D 9 100 μmol/L, creatinine N‐methyl‐D 3 500 μmol/L, deoxycholic acid‐D 4 1.8 μmol/L, D‐fructose 13 C 120 μmol/L, glycine‐ 13 C 2 800 μmol/L, glycocholic acid‐D 4 150 μmol/L, hippuric acid 15 N 500 μmol/L, kynurenine‐D 4 8 μmol/L, leucine‐D 10 300 μmol/L, lysine‐D 4 700 μmol/L, phenylalanine‐D 1 300 μmol/L, proline 15 N 700 μmol/L, serine‐D 3 450 μmol/L, tryptophan‐D 5 250 μmol/L and uric acid‐ 15 N 2 500 μmol/L) was placed into autosampler filter vials (0.45 μm PTFE, Thomson Instrument Company, Oceanside, CA, USA) and 200 μL of urine sample were added. Depending on the acquisition method either 200 μL of a 1:1 (v/v) mixture of eluents A and B (for measurement on the HSST column) or C and D (for measurement on the HILIC column, see Section ) was added.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Urine samples of the experimental nights after placebo and GHB intake of 19 participants (sample of one participant was unavailable) were thawed at room temperature and vortexed for 20 seconds. Forty μL of the IS mix (adenosine ribose‐D 1 15 μmol/L, arginine‐ 13 C 6 300 μmol/L, caffeine 3‐methyl‐ 13 C 200 μmol/L, carnitine trimethyl‐D 9 100 μmol/L, creatinine N‐methyl‐D 3 500 μmol/L, deoxycholic acid‐D 4 1.8 μmol/L, D‐fructose 13 C 120 μmol/L, glycine‐ 13 C 2 800 μmol/L, glycocholic acid‐D 4 150 μmol/L, hippuric acid 15 N 500 μmol/L, kynurenine‐D 4 8 μmol/L, leucine‐D 10 300 μmol/L, lysine‐D 4 700 μmol/L, phenylalanine‐D 1 300 μmol/L, proline 15 N 700 μmol/L, serine‐D 3 450 μmol/L, tryptophan‐D 5 250 μmol/L and uric acid‐ 15 N 2 500 μmol/L) was placed into autosampler filter vials (0.45 μm PTFE, Thomson Instrument Company, Oceanside, CA, USA) and 200 μL of urine sample were added. Depending on the acquisition method either 200 μL of a 1:1 (v/v) mixture of eluents A and B (for measurement on the HSST column) or C and D (for measurement on the HILIC column, see Section ) was added.…”
Section: Methodsmentioning
confidence: 99%
“…24,25 Two different chromatographic systemsreversed phase (HSST) and HILICin both positive and negative ionization mode were chosen to cover as many small molecules as possible. The applied screening method has been extensively examined recently on analyte selection, detectability and sensitivity 20 and was already successfully applied to other untargeted and targeted studies of the metabolome. [26][27][28] For peak picking and deconvolution,…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…The study data were obtained by untargeted data acquisition methods using LC-HRMS with two chromatographic columns in the positive and negative ionization modes as commonly applied in untargeted metabolomic studies [ 2 ]. All samples were analyzed as described in previously published studies [ 6 , 22 ] and in randomized order on a Thermo Fischer Ultimate 3000 UHPLC system (Thermo Fischer Scientific, San Jose, CA), coupled to a high-resolution (HR) time-of-flight (TOF) instrument system (TripleTOF 6600, Sciex, Concord, ON, Canada). Methodological details and performance evaluation have been described in detail elsewhere [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
“…All samples were analyzed as described in previously published studies [ 6 , 22 ] and in randomized order on a Thermo Fischer Ultimate 3000 UHPLC system (Thermo Fischer Scientific, San Jose, CA), coupled to a high-resolution (HR) time-of-flight (TOF) instrument system (TripleTOF 6600, Sciex, Concord, ON, Canada). Methodological details and performance evaluation have been described in detail elsewhere [ 22 ]. In brief, chromatographic separation was achieved by using reversed-phase (Xselect HSST RP-C18 (150 mm × 2.1 mm i.d.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation