1970
DOI: 10.1021/ac60291a032
|View full text |Cite
|
Sign up to set email alerts
|

Analytical method for polynuclear aromatic compounds in coke oven effluents by combined use of gas chromatography and ultraviolet absorption spectrometry

Abstract: A routine method was developed to measure polynuclear aromatic compounds in coke oven effluents. Although other techniques are involved, the method is designated as a GC/UV procedure. In practice,

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

1972
1972
1986
1986

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(10 citation statements)
references
References 9 publications
0
10
0
Order By: Relevance
“…These studies include both gravimetric determination of the benzene soluble fraction of air filter samples and analysis of one or a few components by gas, liquid or thin layer chromatography. A combined gas chromatographic/ultraviolet spectroscopic method for the determination of PAH in coke oven effluents has also been proposed (18). The benzene soluble method has been shown to be inaccurate (19) and does not correlate well with the analytical determination of PAH (17).…”
mentioning
confidence: 99%
“…These studies include both gravimetric determination of the benzene soluble fraction of air filter samples and analysis of one or a few components by gas, liquid or thin layer chromatography. A combined gas chromatographic/ultraviolet spectroscopic method for the determination of PAH in coke oven effluents has also been proposed (18). The benzene soluble method has been shown to be inaccurate (19) and does not correlate well with the analytical determination of PAH (17).…”
mentioning
confidence: 99%
“…The desired compounds (Table IV) are trapped in a manner previously described (8). The trapped compounds are washed from the stainless steel traps into UV cells with cyclohexane to a volume of 3.0 ml.…”
Section: Constitution Of Petroleum Pitch Volatilesmentioning
confidence: 99%
“…The trapped compounds are washed from the stainless steel traps into UV cells with cyclohexane to a volume of 3.0 ml. After UV spectra are obtained, the trapped compounds are quantified (8). for pyrene to f 2 1 % for 1,2-benzanthracene.…”
Section: Constitution Of Petroleum Pitch Volatilesmentioning
confidence: 99%
See 1 more Smart Citation
“…Qualitative identification of GC effluents have also employed Raman (146) and UV spectrometry (834), NMR (1017), and thin-layer chromatography (465). Spots separated on a TLC plate may be introduced into a gas chromatograph for further separation and identification (242).…”
Section: Detectorsmentioning
confidence: 99%