2018 International Conference on Control, Artificial Intelligence, Robotics &Amp; Optimization (ICCAIRO) 2018
DOI: 10.1109/iccairo.2018.00044
|View full text |Cite
|
Sign up to set email alerts
|

Analyzing the Efficiency of Neutral Treatment with Resistor and Shunt Circuit Breaker in a MV Distribution Substation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…The maximum single-phase earth fault current occurs when the network gets the maximum total length of connections. This mode is typical for the post-emergency mode of the substation, that is, when the automatic transfer switch is triggered or the sectional switch is deliberately turned on by the operating personnel [10].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The maximum single-phase earth fault current occurs when the network gets the maximum total length of connections. This mode is typical for the post-emergency mode of the substation, that is, when the automatic transfer switch is triggered or the sectional switch is deliberately turned on by the operating personnel [10].…”
Section: Methodsmentioning
confidence: 99%
“…In this case, any device start-up, arrival of a discrete signal, detection of an internal malfunction is recorded in the event memory with the assignment of the date and time of the moment of detection. The ability to record the presence of faults in the event archive is a very useful function for a substation without permanent personnel on duty [10].…”
Section: Centralized Protection Of Sirius-ozzmentioning
confidence: 99%
“…Failures over 3 minutes are due to internal causes that could have been avoided: rehabilitation of electrical lines, insulation maintenance and equipment, and incorrect correlation of protection systems between the user and the distributor (DEO) [1].…”
Section: Fault Event Analysesmentioning
confidence: 99%
“…Vulnerability has been analyzed on the basis of risk and impact concepts. In this sense, evaluation matrices have been defined and proposed according to the number of affected consumers, the duration of the remediation and the probability of occurrence of a defect [1]. Analyzing the statistical data related to the events occurring in the stoma station for a period of about 2 years before 2017 and studying the behavior of the resistor treatment method in the same period [3], it was proposed to modify the neutral treatment solution by switching to the coil treated with the suppression coil, solution implemented since September / October 2017.…”
Section: Fault Event Analysesmentioning
confidence: 99%
See 1 more Smart Citation