2015
DOI: 10.1016/j.sna.2015.02.037
|View full text |Cite
|
Sign up to set email alerts
|

Angled-focused 45MHz PMN-PT single element transducer for intravascular ultrasound imaging

Abstract: A transducer with an angled and focused aperture for intravascular ultrasound imaging has been developed. The acoustic stack for the angled-focused transducer was made of PMN-PT single crystal with one matching layer, one protective coating layer, and a highly damped backing layer. It was then press-focused to a desired focal length and inserted into a thin needle housing with an angled tip. A transducer with an angled and unfocused aperture was also made, following the same fabrication procedure, to compare t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
21
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 36 publications
(21 citation statements)
references
References 28 publications
0
21
0
Order By: Relevance
“…Angled-focused single-element transducer was another choice to improve IVUS lateral imaging resolution. As reported, the lateral resolution was improved from 270  μ m to 120  μ m with the angled-focused 45 MHz PMN-PT single-element transducer [11]. But the single crystal or PZT are fragile and easy to crack in the process, which would affect the transducer performance and yield, while 1-3 piezocomposite will be an alternative choice for the active material, which can have high frequency, low acoustic impedance, and wide bandwidth [12, 13].…”
Section: Introductionmentioning
confidence: 77%
“…Angled-focused single-element transducer was another choice to improve IVUS lateral imaging resolution. As reported, the lateral resolution was improved from 270  μ m to 120  μ m with the angled-focused 45 MHz PMN-PT single-element transducer [11]. But the single crystal or PZT are fragile and easy to crack in the process, which would affect the transducer performance and yield, while 1-3 piezocomposite will be an alternative choice for the active material, which can have high frequency, low acoustic impedance, and wide bandwidth [12, 13].…”
Section: Introductionmentioning
confidence: 77%
“…Increase in the center frequency of the transducers requires the reduction of thickness [64,[117][118][119]. It causes the impedance of the transducer to approach zero resulting in a severe electrical impedance mismatch.…”
Section: Filter Structure Based Networkmentioning
confidence: 99%
“…An ultrasonic transducer/array is a crucial component of an ultrasonic scanner such as those widely used in clinical diagnosis [1-7]. There has been a growing interest in transducers in the frequency range higher than 100 MHz for applications in single cell analysis, acoustic trapping, and studying mechanotransduction with improved lateral resolution [8-12].…”
Section: Introductionmentioning
confidence: 99%