Anterior chamber depth measurement: A-scan versus optical methods

Abstract: There was good agreement between results obtained with 3 methods based on optical principles. Considering the basic and simple measurement principle of these instruments, they appear to provide the correct result. The A-scan equipment used in this study is unsuitable for determination of ACD in eyes with PMMA IOLs.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
39
0
1

Year Published

2002
2002
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 80 publications
(44 citation statements)
references
References 10 publications
4
39
0
1
Order By: Relevance
“…Orbscan devices have also previously been shown to provide accurate and reproducible results of ocular structures when compared to ultrasound, optical pachymetry, Scheimpflug imaging and the IOLMaster [22,[34][35][36][37][38][39]. Measurements of anterior chamber angles with the Orbscan have been found not to be affected by refractive status [40], which is in line with the results of this study since all estimations of anterior chamber angle were possible in all subjects with KC.…”
Section: Discussionsupporting
confidence: 87%
“…Orbscan devices have also previously been shown to provide accurate and reproducible results of ocular structures when compared to ultrasound, optical pachymetry, Scheimpflug imaging and the IOLMaster [22,[34][35][36][37][38][39]. Measurements of anterior chamber angles with the Orbscan have been found not to be affected by refractive status [40], which is in line with the results of this study since all estimations of anterior chamber angle were possible in all subjects with KC.…”
Section: Discussionsupporting
confidence: 87%
“…Examiner (reference) ACD (mm) Kriechbaum et al (2003) 2.87 Ne´meth et al (2003) 2.91 ± 0.50 Reddy et al (2004) 2.87 ± 0.55 Wong et al (2003) 2.89 Koranyi et al (2002) 3.05 ± 0.36 Auffarth et al (1997) 3.27 ± 0.57 Table 4. Axial length (AL) using contact ultrasound biometry, as reported in the literature.…”
Section: Referencesmentioning
confidence: 99%
“…The instrument provides information about the cornea, iris, lens, anterior chamber angle, and ACD. Orbscan devices have been shown to provide accurate and reproducible results when compared to ultrasound [14][15][16][17], optical pachymetry [14,15], Scheimpflug imaging [7,13,15,18], and the IOLMaster [16][17][18][19]. Measurements of ACD are not affected by refractive status [20].…”
Section: Introductionmentioning
confidence: 99%