2018
DOI: 10.14260/jemds/2018/803
|View full text |Cite
|
Sign up to set email alerts
|

Anterior Clinoid Process and Optic Strut- A Morphometric Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
11
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(14 citation statements)
references
References 8 publications
2
11
1
Order By: Relevance
“…These average values were compatible with adult data range (5.30-12.50 mm for the length, 5.60-12.40 mm for the width, 39.67-42.09 degrees for the angle) in the literature (Supplementary Table 9, Supplemental Digital Content 9, http:// links.lww.com/SCS/E320). 13,15,[19][20][21]23,24,[31][32][33][34][35][36][37][38][39][40][41] Our mean width and length values were greater than fetal values (4.65 ± 0.94 mm for the width, 3.67 ± 0.82 mm for the length) reported by Beger et al, 19 but the mean angle value in this study was smaller than that (59.57 ± 8.03 degrees) in their study. 19 Therefore, we think that the length and width of ACP increase after birth up to adulthood, while its angle narrows.…”
Section: Discussioncontrasting
confidence: 72%
“…These average values were compatible with adult data range (5.30-12.50 mm for the length, 5.60-12.40 mm for the width, 39.67-42.09 degrees for the angle) in the literature (Supplementary Table 9, Supplemental Digital Content 9, http:// links.lww.com/SCS/E320). 13,15,[19][20][21]23,24,[31][32][33][34][35][36][37][38][39][40][41] Our mean width and length values were greater than fetal values (4.65 ± 0.94 mm for the width, 3.67 ± 0.82 mm for the length) reported by Beger et al, 19 but the mean angle value in this study was smaller than that (59.57 ± 8.03 degrees) in their study. 19 Therefore, we think that the length and width of ACP increase after birth up to adulthood, while its angle narrows.…”
Section: Discussioncontrasting
confidence: 72%
“…However, ACP-L was smaller in CM-I (11.12 AE 2.09 mm) than the control group (12.79 AE 2.43 mm; p < 0.001). Our average values for both groups were compatible with previous studies (►Table 7), 10,12,18,19,21,22,[39][40][41][42][44][45][46][47][48][49][50] in where the mean data range was presented between 5.30 and 12.50 mm. In contrast to ACP-L value, ACP-A, OS-L, and Dis-ACP-OS were found greater in CM-I than the control group.…”
Section: Sellar Region In Chiari Typesupporting
confidence: 92%
“…Dis-ACP-OS was measured as 6.04 AE 0.92 mm for CM-I and 5.60 AE 1.46 for the control group (p ¼ 0.020). Our values of these parameters for both groups were compatible with previous studies (►Table 7), 10,18,41,43,[48][49][50] in where the mean data range was given as 3.94 to 6 mm for OS-L and as 5.80 to 13.84 mm for Dis-ACP-OS. On the other hand, the wide range between average values given in the previous articles may be owing to differences in study populations (e.g., age, sex, region, and side) or methods (CT, cone-beam computed tomography, digital caliper, etc.).…”
Section: Sellar Region In Chiari Typesupporting
confidence: 91%
“…13 Similar observations were reported in Nepal, Indian, Japan, and Korean skulls, respectively. [14][15][16][17] Cecen et al classified ACP into three types: type I ACPs short, wide, and wide-angled; type II ACPs long, narrow, and narrow-angled; and type III ACPs. 18 In our study the length of the right ACP was 11.31 AE 2.76 mm, the left ACP was 11.54 AE 2.86 mm, the width of the right ACP was 7.70 AE 1.66 mm, the left ACP was 7.64 AE 1.67 mm, which means that the length of ACP of skulls is longer and the width is less than the average calculated in other countries.…”
Section: Discussionmentioning
confidence: 99%
“… 13 Similar observations were reported in Nepal, Indian, Japan, and Korean skulls, respectively. 14 15 16 17 Cecen et al classified ACP into three types: type I ACPs short, wide, and wide-angled; type II ACPs long, narrow, and narrow-angled; and type III ACPs. 18 …”
Section: Discussionmentioning
confidence: 99%