2006
DOI: 10.3390/s6080808
|View full text |Cite
|
Sign up to set email alerts
|

Antibody Immobilization on Waveguides Using aFlow–Through System Shows Improved Listeria monocytogenesDetection in an Automated Fiber Optic Biosensor: RAPTORTM

Abstract: Recent outbreaks of food borne illnesses continue to support the need for rapid and sensitive methods for detection of foodborne pathogens. A method for detecting Listeria monocytogenes in food samples was developed using an automated fiber-optic-based immunosensor, RAPTOR ™. Detection of L. monocytogenes in phosphate buffered saline (PBS) was performed to evaluate both static and flow through antibody immobilization methods for capture antibodies in a sandwich assay. Subsequent detection in frankfurter sample… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
29
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(29 citation statements)
references
References 18 publications
0
29
0
Order By: Relevance
“…This is further dependent on the type of immobilization technique used. Stronger antibodybacterial binding is indicated by lower K d values, which in turn implies higher sensitivity of the biosensor [36].…”
Section: Principle Of Operationmentioning
confidence: 99%
“…This is further dependent on the type of immobilization technique used. Stronger antibodybacterial binding is indicated by lower K d values, which in turn implies higher sensitivity of the biosensor [36].…”
Section: Principle Of Operationmentioning
confidence: 99%
“…In sandwich assay, the effective disassociation constant (K d ) and the binding valences for static mode of antibody immobilization in spiked PBS samples was 4×10 5 CFU/mL and 4.9 as compared to 7×10 4 CFU/mL and 3.9 for flow through method of antibody immobilization. Thus the sensitive flow-through immobilization method was used to test food samples, which could detect 5×10 5 CFU/mL of L. monocytogenes in frankfurter sample (Nanduri et al 2006). A surface plasmon resonance based immunosensor for the rapid, sensitive and selective detection of generic E. coli in water samples was developed.…”
Section: Detection Of Pathogensmentioning
confidence: 99%
“…A hill plot was constructed using the dose response curves [22,28,34,35] to determine the binding kinetics (K d and n H ) (Fig. 4).…”
Section: Salmonella Enteridis Eschericia Colimentioning
confidence: 99%