2022
DOI: 10.1007/s11082-021-03505-7
|View full text |Cite
|
Sign up to set email alerts
|

Antimonene-gold based twin-core SPR sensor with a side-polished semi-arc groove dual sensing channel: an investigation with 2D material

Abstract: We propose surface plasmon resonance (SPR) based single-side polished photonic crystal fiber (SSP-PCF) sensor for low as well as high refractive index (RI) sensing. To achieve this, an active metal gold (Au) is deposited on the PCF's flat narrow channels to form a dual-sensing channel. Following that, a thin nanolayer antimonene is deposited on Au, as its buckled honeycomb lattice structure aids in the trapping of numerous biomolecules. For the sensing range of 1.27 to 1.39, numerical results show that the wav… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…Recently, surface plasmon resonance-(SPR-) based PCF sensors have been reported, showing noticeable changes in outputs for small changes of refractive index among diferent analytes [9][10][11][12][13][14]. Resonance wavelength and peak confnement loss are very sensitive to RI of the analytes in the SPR-PCF platform [9][10][11][12][13][14].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Recently, surface plasmon resonance-(SPR-) based PCF sensors have been reported, showing noticeable changes in outputs for small changes of refractive index among diferent analytes [9][10][11][12][13][14]. Resonance wavelength and peak confnement loss are very sensitive to RI of the analytes in the SPR-PCF platform [9][10][11][12][13][14].…”
Section: Resultsmentioning
confidence: 99%
“…Recently, surface plasmon resonance-(SPR-) based PCF sensors have been reported, showing noticeable changes in outputs for small changes of refractive index among diferent analytes [9][10][11][12][13][14]. Resonance wavelength and peak confnement loss are very sensitive to RI of the analytes in the SPR-PCF platform [9][10][11][12][13][14]. As a result, a slight change in RI of the analytes forces to the resonance wavelength to shift right or left and the peak of the confnement loss to higher or lower level [9][10][11][12][13][14].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations