2022
DOI: 10.1016/j.jscai.2022.100349
|View full text |Cite
|
Sign up to set email alerts
|

Aortic Valve Calcium Score Is Associated With Acute Stroke in Transcatheter Aortic Valve Replacement Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 34 publications
0
7
0
Order By: Relevance
“…One study with transcranial Doppler in TAVI showed that cerebral embolism often occurs during prosthetic valve positioning and valve deployment [ 10 ]. Aortic valve calcium score, measured by CT, has been reported to be an independent risk factor for TAVI-related stroke [ 11 ]. Our case had a high aortic valve calcium score of 3140 Agatston units, suggesting that the patient was at a high risk of stroke.…”
Section: Discussionmentioning
confidence: 99%
“…One study with transcranial Doppler in TAVI showed that cerebral embolism often occurs during prosthetic valve positioning and valve deployment [ 10 ]. Aortic valve calcium score, measured by CT, has been reported to be an independent risk factor for TAVI-related stroke [ 11 ]. Our case had a high aortic valve calcium score of 3140 Agatston units, suggesting that the patient was at a high risk of stroke.…”
Section: Discussionmentioning
confidence: 99%
“…We utilize calcium score cutoffs of 2065 in males and 1275 in females for severe AS [22]. Recent studies have revealed that an elevated pre-TAVR calcium score from computed tomography is an independent risk factor for acute stroke, thus providing prognostication capabilities as well [23]. Computed tomography also provides the added benefit of a three-dimensional visualization of the valve and left ventricular outflow tract as two-dimensional imaging often results in underestimation of the severity of stenosis.…”
Section: Pre-procedural Work-upmentioning
confidence: 99%
“…The balloon-expandable SAPIEN 3 Ultra transcatheter aortic valve is the fifthgeneration valve in the Sapien series and is available in four sizes (20,23,26, and 29 mm). Its design consists of three bovine pericardial tissue leaflets with a cobalt-chromium frame.…”
Section: Sapien 3 Ultra (Edwards Lifesciences)mentioning
confidence: 99%
See 1 more Smart Citation
“…AVCS is reported to be a useful prognostic imaging marker in AS and is associated with higher rates of mortality during follow-up, with a hazard ratio of 2.11 as a binary threshold[ 47 ]. In addition, a higher AVCS is reported to be an independent risk factor for acute stroke after transcatheter aortic valve replacement[ 48 ].…”
Section: Cardiac Ct For Diagnosis Of Specific Cardioembolic Sourcesmentioning
confidence: 99%