Apparent power decompositions of three-phase power supply system to develop control algorithms of shunt active filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…In Fig. 2 dotted line shows the level of reduction in the efficiency of the power supply system for the load with a power factor 0.5 Λ = built according to (10).…”
Section: F T Imentioning
confidence: 99%
See 2 more Smart Citations
“…In Fig. 2 dotted line shows the level of reduction in the efficiency of the power supply system for the load with a power factor 0.5 Λ = built according to (10).…”
Section: F T Imentioning
confidence: 99%
“…From (2), it follows that in the case of asymmetric non-sinusoidal voltages at PCC, the formation of the power system active current is accompanied by the energy consumption of the multiphase source higher harmonics and negative and zero sequences symmetric components of the network frequency, which the standard IEEE Std 1459-2010 [2] recommends avoiding. The paper [10] presents algorithms of active filtration, forming the vectors of source currents following the recommended by this standard of apparent power decompositions for permissible quadratic components. In particular, the transfer of energy to the load at the frequency of the main harmonics by the positive sequence component of the phase voltage vector…”
Section: Figmentioning
confidence: 99%
See 1 more Smart Citation
“…In the case of compensation of inactive current by means of filtration, we will have a decrease in the power loss P  in the transmission line, which can be characterized [10] by the coefficient of gain on the power loss:…”
Section: Vectors Of Active Currents In Phase Coordinatesmentioning
confidence: 99%
“…The transition from two-coordinate vectors in symmetric coordinates to three-coordinate complex vectors in phase coordinates is carried out by multiplying on the matrix . (10) Consumption from an asymmetric sinusoidal Fryze current source does not eliminate the pulsations of active power [5]. Its instantaneous value can be determined [2] using the vector…”
Section: Vectors Of Active Currents In Phase Coordinatesmentioning
confidence: 99%