2000
DOI: 10.1039/a905906g
|View full text |Cite
|
Sign up to set email alerts
|

Application of a low power/reduced pressure helium ICP ionization source for mass spectrometric detection of organobromine compounds and derivatized organotin compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2000
2000
2009
2009

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 19 publications
0
20
0
Order By: Relevance
“…GC/ICP MS has first been applied for the analysis of volatile organobromo compounds in environmental samples (Evans & Caruso, 1993; Waggoner et al, 1999; Hardy, 2002; Schwarz & Heumann, 2002; Profrock et al, 2004). Instrumentation has been directed to the design of new GC/plasma interfaces, use of low power plasmas to obtain molecular structural information and the development of more sensitive and robust analytical methodologies.…”
Section: Application Of Mass Spectrometry In the Analysis Of Pbdesmentioning
confidence: 99%
“…GC/ICP MS has first been applied for the analysis of volatile organobromo compounds in environmental samples (Evans & Caruso, 1993; Waggoner et al, 1999; Hardy, 2002; Schwarz & Heumann, 2002; Profrock et al, 2004). Instrumentation has been directed to the design of new GC/plasma interfaces, use of low power plasmas to obtain molecular structural information and the development of more sensitive and robust analytical methodologies.…”
Section: Application Of Mass Spectrometry In the Analysis Of Pbdesmentioning
confidence: 99%
“…One possible solution is the use of one dynamic plasma as an ionization source instead of two 'static' ionization sources [9][10][11][12][13]. A possible dynamic plasma source is the pulsed glow discharge [14,15].…”
Section: Introductionmentioning
confidence: 99%
“…Caruso et al [192,193] have also used GC-LP-ICPMS to obtain elemental and structural information from chromatographic eluents. Limits of detection at the pg level were obtained for organobromine compounds when helium was used as the plasma gas [193].…”
Section: Reduced-pressure Plasmas As Tunable Ion Sourcesmentioning
confidence: 99%
“…Limits of detection at the pg level were obtained for organobromine compounds when helium was used as the plasma gas [193]. In addition, the authors demonstrated the capability of the system to produce tunable fragmentation of organotin compounds by varying the helium/argon plasmagas ratio [192].…”
Section: Reduced-pressure Plasmas As Tunable Ion Sourcesmentioning
confidence: 99%