2020
DOI: 10.1002/rcm.8710
|View full text |Cite
|
Sign up to set email alerts
|

Application of a novel cyclic ion mobility‐mass spectrometer to the analysis of synthetic polymers: A preliminary evaluation

Abstract: Rationale Mass spectrometry (MS) is often employed in the characterisation of synthetic polymers. As polymer architecture becomes more complex, ion mobility (IM) is increasingly being coupled with MS to provide an additional dimension of separation, along with structural information. In this study, we explore the use of a novel cyclic ion mobility (cIM) mass spectrometer for the analysis of a co‐polymer sample. Methods A solution of poly(ethylene glycol)–poly(propylene glycol) random co‐polymer (PEG‐ran‐PPG) w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 47 publications
0
8
0
Order By: Relevance
“…Following this single-cycle separation, we sliced/selected the closed conformer, while simultaneously ejecting out the open conformer, and vice versa in a separate experiment. For more details on how slicing/selecting species is performed using the flexible capabilities of the cIMS array, please refer to refs , , , and . Each conformer was then individually subjected to a 35 m cIMS-MS separation.…”
Section: Resultsmentioning
confidence: 99%
“…Following this single-cycle separation, we sliced/selected the closed conformer, while simultaneously ejecting out the open conformer, and vice versa in a separate experiment. For more details on how slicing/selecting species is performed using the flexible capabilities of the cIMS array, please refer to refs , , , and . Each conformer was then individually subjected to a 35 m cIMS-MS separation.…”
Section: Resultsmentioning
confidence: 99%
“…The instrument and the cIMS device were described in detail elsewhere (Scheme S1). ,, The cIMS platform allowed for the high reproducibility of the drift time measurements with a general day-to-day deviation of below 2%. Mass spectra were acquired in positive ion mode for m / z 50–1000 and for 3 min, accounting for roughly 180 scans.…”
Section: Methodsmentioning
confidence: 99%
“…Aside from a higher resolving power, a higher number of data points (bins) are beneficial for an accurate description of the IMS-profile of complex isomeric mixtures. A very recent technology is cyclic ion mobility spectrometry (cIMS), allowing for the ions to pass multiple times in a circular traveling wave array, increasing the IMS resolving power by a factor of the square root of the pass number. In combination with an ion storage device before and after the cyclic array as well as with an option for collision-induced dissociation (CID), enormous flexibility is enabled for detailed molecular description.…”
Section: Introductionmentioning
confidence: 99%