2020
DOI: 10.1007/s00216-020-02896-y
|View full text |Cite
|
Sign up to set email alerts
|

Application of direct analysis in real time to study chemical vapor generation mechanisms: reduction of dimethylarsinic(V) acid with aqueous NaBH4 under non-analytical conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…in the absence of dissolved analyte) using SP-ICP-MS. For each plasma, the selected operating conditions provided a compromise in sensitivity for multielemental analysis. An Ar plasma was found to provide signicantly lower LOD (size) than the mixed-gas plasmas, except for 33 S, 31 P, and 44 Ca, where oxygen scavenging by N 2 within the Ar-N 2 plasma signicantly improved the measured LOD (size). With the Ar-N 2 -H 2 plasma, an accompanying loss of sensitivity largely negated the LOD (size) improvement from oxygen scavenging.…”
Section: Sample Introductionmentioning
confidence: 92%
See 1 more Smart Citation
“…in the absence of dissolved analyte) using SP-ICP-MS. For each plasma, the selected operating conditions provided a compromise in sensitivity for multielemental analysis. An Ar plasma was found to provide signicantly lower LOD (size) than the mixed-gas plasmas, except for 33 S, 31 P, and 44 Ca, where oxygen scavenging by N 2 within the Ar-N 2 plasma signicantly improved the measured LOD (size). With the Ar-N 2 -H 2 plasma, an accompanying loss of sensitivity largely negated the LOD (size) improvement from oxygen scavenging.…”
Section: Sample Introductionmentioning
confidence: 92%
“…Chemical vapour generation (CVG) has been applied for a long time, but the mechanisms are still not fully understood. Pagliano et al 31 investigated the mechanism of reduction of dimethylarsinic acid (DMA) with aqueous NaBH 4 under non-analytical conditions, i.e. 1000 μg mL −1 As.…”
Section: Sample Introductionmentioning
confidence: 99%
“…Pagliano et al used DART‐HRMS for the real‐time study of mechanisms of chemical vapor generation 130 . In comparison with analysis by GC‐MS, DART‐MS was able to detect a number of species not detected by traditional techniques, demonstrating ambient techniques are not only capable of significantly faster analysis, but also identifying previously undetected analytes.…”
Section: Applications Of Ambient Ionization Mass Spectrometrymentioning
confidence: 99%
“…hydride generation (HG), solid-phase microextraction) [6][7][8][9][10] separation coupled to a sensitive detector (AFS, AAS, ICP-MS, Orbitrap MS). 7,11,12 However, tedious sample preparation and multistep extraction of As analytes were normally compulsory when using conventional analytical techniques. As a redox-sensitive element, great efforts need to be made for developing extraction procedures and preservation methods for As, because instability and interconversion of As species may occur during these procedures.…”
Section: Introductionmentioning
confidence: 99%