2002
DOI: 10.1007/s00340-002-0991-8
|View full text |Cite
|
Sign up to set email alerts
|

Application of mid-infrared cavity-ringdown spectroscopy to trace explosives vapor detection using a broadly tunable (6-8 μm) optical parametric oscillator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
67
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 132 publications
(67 citation statements)
references
References 1 publication
0
67
0
Order By: Relevance
“…One interferogram is acquired in 0.5 s, and the subsequent fast Fourier transform (FFT) yields a spectrum containing 6000 spectral elements. For measurements of absorption spectra of C 2 H 2 , CH 4 , and N 2 O in nitrogen (N 2 ), the cavity is filled with the gas mixture to the desired pressure, and the analyte spectrum is recorded while constant flow of the gas through the cavity is maintained. After the analyte spectrum is taken, the cavity is evacuated and then refilled to the same pressure with pure N 2 , and a reference spectrum is recorded.…”
Section: Detection System and Signal Acquisitionmentioning
confidence: 99%
See 3 more Smart Citations
“…One interferogram is acquired in 0.5 s, and the subsequent fast Fourier transform (FFT) yields a spectrum containing 6000 spectral elements. For measurements of absorption spectra of C 2 H 2 , CH 4 , and N 2 O in nitrogen (N 2 ), the cavity is filled with the gas mixture to the desired pressure, and the analyte spectrum is recorded while constant flow of the gas through the cavity is maintained. After the analyte spectrum is taken, the cavity is evacuated and then refilled to the same pressure with pure N 2 , and a reference spectrum is recorded.…”
Section: Detection System and Signal Acquisitionmentioning
confidence: 99%
“…5 show the measured spectra (normalized to a reference spectrum) of several combination bands of C 2 H 2 (Fig. 5a), the 2ν 4 overtone band of CH 4 (Fig. 5b), and the 2ν 1 overtone band of N 2 O (Fig.…”
Section: Commercial Gas Standardsmentioning
confidence: 99%
See 2 more Smart Citations
“…91 Compact OPO system was also used for remote sensing explosives vapor detection at ppb level. 92 Other than conventional absorption spectroscopy, there are many new spectroscopic technologies developed, especially the frequency combs technique. 10,12 Mid-IR OPO shows great advantages in a new very sensitive absorption spectroscopy technique, called cavity-ring-down spectroscopy.…”
Section: Architecture Of Opomentioning
confidence: 99%