2011
DOI: 10.1002/dta.329
|View full text |Cite
|
Sign up to set email alerts
|

Application of multiwalled carbon nanotubes/ionic liquid modified electrode for amperometric determination of sulfadiazine

Abstract: A highly sensitive amperometric sulfadiazine sensor based on coating multiwalled carbon nanotubes (MWCNTs) and N-octyl-pyridinium-hexafluorophosphate (OPPF(6)) ionic liquid composite on a glassy carbon (GC) electrode is described. The MWCNTs/OPPF(6) composite contributed new properties to electrochemical sensors by combining the advantages of both ionic liquids and MWCNTs. Compared with bare GC electrode, the electrocatalytic activity of MWCNTs/OPPF(6) generated a greatly improved electrochemical detection of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 33 publications
0
7
1
Order By: Relevance
“…The analytical performance of TiC/BN/GCE was compared to that of the previously reported modified electrodes, which is listed in Table . The obtained results in this work are better than those of some previously published studies, ,, indicating the good electrochemical activity of the TiC/BN-based sensor.…”
Section: Resultscontrasting
confidence: 64%
“…The analytical performance of TiC/BN/GCE was compared to that of the previously reported modified electrodes, which is listed in Table . The obtained results in this work are better than those of some previously published studies, ,, indicating the good electrochemical activity of the TiC/BN-based sensor.…”
Section: Resultscontrasting
confidence: 64%
“…Due to the bifunctional modification, the extraction material is considerably more hydrophilic than conventional PS/DVB polymers and thus easily wettable with water. This polymeric material with a weak ion exchanger provides a wide range of pH stability (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14), protection of the phase from acidic or basic solvents, and its high surface means very high binding capacity (nearly five times higher than silica-based adsorbents). Therefore, the material has a phase which is highly effective for small molecule retention and for hydrophilic layer which is non-adsorptive for proteins.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, the extraction material (Chromabond 1 Easy) was obtained from Macherey-Nagel (D€ uren, Germany) and was dry packed in a stainless steel column cartridge (30 Â 4.6 mm id). This material is a polar, bifunctionally modified PS/DVB copolymer with a weak anion exchanger, (specific surface 650-700 m 2 g À1 , particle size 80 mm, pore size 50 Å, pH stability [1][2][3][4][5][6][7][8][9][10][11][12][13][14]. Before packing, the empty cartridge was cleaned in an ultrasonic methanol bath.…”
Section: Columnsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this case, MWCNT and OPy.PF 6 were simply mixed (1:9 w/w), dispersed in DMF, and deposited in a clean GCE, being applied for drug detection in strongly acidic conditions at +0.9 V, presenting a LOD of 0.21 μmol L −1 . The selectivity parameter was tested with ascorbic acid, and since it oxidized at a lower potential (+0.35 V) compared to the sulfadiazine, its interference was eliminated by signal subtraction [ 63 ]. Linear sweep voltammetry (LSV) is another technique employed, however limitedly.…”
Section: (Bio)sensing Strategies For Pharmaceuticals Using Electroche...mentioning
confidence: 99%