2011
DOI: 10.1007/s10973-010-1274-y
|View full text |Cite
|
Sign up to set email alerts
|

Application of thermal analysis and pyrolysis coupled to GC/MS in the qualification of simvastatin pharmaceutical raw material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
1

Year Published

2011
2011
2016
2016

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 9 publications
0
8
0
1
Order By: Relevance
“…10,11,13,14 Thermogravimetry experiments carried out at 10 K/min indicate that after fusion SV undergoes pyrolysis with onset at approximately 443 or 476 K in dynamic air or dynamic N 2 atmospheres, respectively. 10,23 In this work, a comprehensive experimental study of the thermal stability of SV under different atmospheres with identification of the major degradation products is reported. In addition to isothermal tests carried out in glass ampules, dynamic and isothermal experiments were also carried out by differential scanning calorimetry (DSC) and Calvet-drop microcalorimetry, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…10,11,13,14 Thermogravimetry experiments carried out at 10 K/min indicate that after fusion SV undergoes pyrolysis with onset at approximately 443 or 476 K in dynamic air or dynamic N 2 atmospheres, respectively. 10,23 In this work, a comprehensive experimental study of the thermal stability of SV under different atmospheres with identification of the major degradation products is reported. In addition to isothermal tests carried out in glass ampules, dynamic and isothermal experiments were also carried out by differential scanning calorimetry (DSC) and Calvet-drop microcalorimetry, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…4i) occurred at 400°C. Other authors also used DSC coupled to a photovisual system [22][23][24][25] and confirmed the parameters obtained by DSC and TG. This technique is an important tool to confirm events in special melting.…”
Section: Resultsmentioning
confidence: 55%
“…The structures of guanylhydrazones studied in this study are the following: Thermogravimetry (TG) and differential scanning calorimetry (DSC) are thermal techniques widely distributed and used in pharmaceutical analyses. These techniques are used in studies of drug characterization, purity, compatibility studies, polymorphism identification, stability evaluation, thermal decomposition of drugs, and development of pharmaceutical formulations [19][20][21][22][23][24][25][26].…”
Section: Introductionmentioning
confidence: 99%
“…Herbal medicine powder, its products and extracts have been characterized by analytical methods. Scanning electron microscopy (SEM) is used to characterize the morphology and particle size of herbal medicine powder [12,13]; thermal analysis such as thermogravimetry (TG) and differential thermal analysis (DTA) together with pyrolysis coupled to gas chromatography/mass spectrometry is employed to evaluate the quality of pharmaceuticals [14][15][16], as well as atomized extracts of herbal medicine like E. mulungu [17] and distinct brands and batches of Cymbopogon citratus teas [18]. Figure 1 shows the micrographs from samples CAR 01, 02 and 03.…”
Section: Thermal Decomposition Kinetic Interpretationmentioning
confidence: 99%