2020
DOI: 10.1016/j.microc.2020.105443
|View full text |Cite
|
Sign up to set email alerts
|

Application of μ-TLC for speciation of inorganic arsenic by laser ablation inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 58 publications
0
8
0
Order By: Relevance
“…Other methods used hydride generation coupled with ICP—triple quadrupole bypassed the chromatographic separation with very good results in terms of recoveries [ 44 ]. A very interesting procedure was developed by coupling laser ablation with the ICP-MS (LA-ICP-MS) for direct measurement in solid samples of inorganic arsenic species previously separated by thin layer chromatography [ 45 ].…”
Section: Resultsmentioning
confidence: 99%
“…Other methods used hydride generation coupled with ICP—triple quadrupole bypassed the chromatographic separation with very good results in terms of recoveries [ 44 ]. A very interesting procedure was developed by coupling laser ablation with the ICP-MS (LA-ICP-MS) for direct measurement in solid samples of inorganic arsenic species previously separated by thin layer chromatography [ 45 ].…”
Section: Resultsmentioning
confidence: 99%
“…The application of μ-TLC for the speciation of iAs in aqueous media by LA-ICP-MS has also been reported. 34 An As V imprinted polymer was synthesised by copolymerisation of itaconic acid and ethylene glycol di-methacrylate in the presence of As V in acetonitrile assisted by ultrasound. The method used a TLC plate fabricated with the As V imprinted polymer nanoparticles.…”
Section: Elemental Speciation Analysismentioning
confidence: 99%
“…column set at 40 C using a mobile phase of (A) 0.1% TFA in water and (B) 0.1% TFA in AcN under gradient elution. The eluent was mixed with either 77 Se or 34 S via a static mixing piece and introduced directly into the nebuliser or the ICP-MS/MS, operated with O 2 as a reaction gas, to detect 32 S 16 O, 34 S 16 O, 77 Se 16 O and 80 Se 16 O. The analytical performance of postcolumn IDA was compared with external calibration based on matrix-matched standards.…”
Section: Seleniummentioning
confidence: 99%
“…Reasonable extraction efficiencies with relatively low interspecies transformation rates were considered possible if the ultrasonic bath conditions were 150–300 W and 40–60 °C with a 5–10 min extraction time. To separate As III from As V in Iranian mine waters, an As V -specific IIP was prepared 64 and applied to an etched TLC plate to form a set of μTLC plates for subsequent LA-ICP-MS detection. Optimum separation for a 10 μL sample volume was obtained within 10 min with a 1 : 1 acetonitrile : water mobile phase.…”
Section: Water Analysismentioning
confidence: 99%
“…It was claimed that these three RMs are the rst with absolute Mo isotope amount ratios traceable to SI units. Another contribution 222 described the development, uncertainty evaluation and certication of a set of eleven new Zn isotope RMs (GBW04465-04475) with 64 Zn/ 66 Zn ratios ranging from 0.02 to 13. They were gravimetrically prepared from enriched isotopic materials whose composition had been accurately determined by total evaporation TIMS.…”
Section: Reference Materials and Data Qualitymentioning
confidence: 99%