Applying a risk assessment guided evaluation for verifying comprehensive two-dimensional gas chromatography to analyse complex pharmaceuticals

Lukas Schwalb,
Ole Tiemann,
Uwe Käfer
et al.

Abstract: The reliability of analytical results is critical and indispensable when applied in regulated environments such as the pharmaceutical industry. Therefore, analytical workflows must be validated. However, validation guidelines are often designed for quantitative targeted analysis and rarely apply to qualitative untargeted approaches. In this study, we employ a risk assessment approach to identify critical parameters which might influence the qualitative results derived by online derivatisation — comprehensive t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…The GC × GC measurements were carried out on a Pegasus GC-HRT 4D (LECO, St. Joseph, USA). 15,31 In summary, a 60 m BP1 (0.25 mm internal diameter, 0.25 μm film thickness, SGE) column was used in the first dimension and 1.5 m BPX50 (0.1 mm internal diameter, 0.1 μm film thickness, SGE) in the second dimension. Before the measurement, the APIs were mixed with tetramethylammonium hydroxide (1:2 w/v) and diluted 1:10 with a mixture of water/methanol (1:1 v/v).…”
Section: Method 221 Thermogravimetry Fourier-transform Ion Cyclotron ...mentioning
confidence: 99%
See 4 more Smart Citations
“…The GC × GC measurements were carried out on a Pegasus GC-HRT 4D (LECO, St. Joseph, USA). 15,31 In summary, a 60 m BP1 (0.25 mm internal diameter, 0.25 μm film thickness, SGE) column was used in the first dimension and 1.5 m BPX50 (0.1 mm internal diameter, 0.1 μm film thickness, SGE) in the second dimension. Before the measurement, the APIs were mixed with tetramethylammonium hydroxide (1:2 w/v) and diluted 1:10 with a mixture of water/methanol (1:1 v/v).…”
Section: Method 221 Thermogravimetry Fourier-transform Ion Cyclotron ...mentioning
confidence: 99%
“…GCxGC group-type analysis (Figure S13C) revealed distinct DBE-specific structural moieties for each compound class (e.g., thiophene-and benzothiophenesulfonates (DBE 3 and DBE 6, respectively) for CHO 3 S 2 ). Therefore, the abundances of isomers found by GCxGC EI HR-ToF-MS analysis can be summed up to obtain data sets which are comparable to the direct infusion FT-ICR MS data, 31 allowing for an alignment of these data sets according to their assigned sum formulas. This further allows to tentatively transfer the structural elucidation achieved by the GCxGC analysis to the direct infusion ESI(−) data set.…”
Section: Chemical Description Of the Ammonium Bituminosulfonatesmentioning
confidence: 99%
See 3 more Smart Citations