2016
DOI: 10.1016/j.snb.2016.02.036
|View full text |Cite
|
Sign up to set email alerts
|

Aptamer-based sandwich assay for on chip detection of Ochratoxin A by an array of amorphous silicon photosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
40
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 51 publications
(46 citation statements)
references
References 37 publications
0
40
0
Order By: Relevance
“…Gold nanoparticles [77], dendrimers [78], quantum dots [79], and graphene oxide [80] have been employed in the mycotoxin sensing. In combination with nanoparticles, specific aptamers were also used to develop some fluorescence thin film sensors for mycotoxin detection [81,82]. The aptamer consists of a synthetic oligonucleotide ligand (either single stranded DNA (ssDNA) or RNA) that comprises less than 80 nucleotides and with less than 25 kDa and are known to exhibit high specificity and strong binding affinity [83].…”
Section: Fluorescence Sensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Gold nanoparticles [77], dendrimers [78], quantum dots [79], and graphene oxide [80] have been employed in the mycotoxin sensing. In combination with nanoparticles, specific aptamers were also used to develop some fluorescence thin film sensors for mycotoxin detection [81,82]. The aptamer consists of a synthetic oligonucleotide ligand (either single stranded DNA (ssDNA) or RNA) that comprises less than 80 nucleotides and with less than 25 kDa and are known to exhibit high specificity and strong binding affinity [83].…”
Section: Fluorescence Sensorsmentioning
confidence: 99%
“…The interaction of this wave with free oscillating electrons at the metal film surface at a specific angle of incidence will cause the excitation of the plasmon surface, resulting in a decrease in the reflected light intensity. A SPR system thus detects changes in the refractive index of the surface layer of a solution in contact with the sensor chip [81]. Figure 2 (reproduced with permission from reference [91] ©Nature, 2018) shows the SPR biosensor principle, including a typical set-up as well as a common binding cycle.…”
Section: Surface Plasmon Resonance (Spr) Sensorsmentioning
confidence: 99%
“…At this point, the PDMS stub, previously obtained, was bonded to the poly 2-(hydroxyethyl methacrylate) (PHEMA) functionalized with succinic anhydride functionalized glass substrate [23]. After the bonding between the PDMS serpentine channel and the PHEMA-functionalized glass slide, the microfluidic channel was further modified to immobilize streptavidin [7].…”
Section: Loc Structure and Fabricationmentioning
confidence: 99%
“…An alternative approach to antibodies, in biomolecular recognition, is represented by aptamers. Aptamers are artificial single-stranded DNA (ssDNA) or RNA sequences that fold into secondary and tertiary structures allowing their binding to selected targets with extremely high specificity [7], [8]. Due to their chemical structure, aptamers are much easier to be chemically modified with functional groups according to different purposes and are much more stable than antibodies.…”
mentioning
confidence: 99%
“…2 . Further details on the photodiode array fabrication can be found in [47]. It can be deduced from the Figure 12 that the photocurrent initially decreases due to creation of two types of defects under blue light illumination.…”
mentioning
confidence: 99%