2022
DOI: 10.1039/d2ra02420a
|View full text |Cite
|
Sign up to set email alerts
|

Array-based chemical warfare agent discrimination via organophosphorus-H2O2 reaction-regulated chemiluminescence

Abstract: A chemical warfare agent sensor array based on organophosphorus-H2O2 reaction-regulated chemiluminescence is proposed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 47 publications
0
5
0
Order By: Relevance
“…119 Recently, an array-based CWA discrimination was realized based on organophosphorus-H 2 O 2 reaction-regulated chemiluminescence. 120 Disease Identification. Biomarkers are indicators that can determine the process of certain diseases, which are widely studied in clinical diagnosis and disease identification.…”
Section: ■ Applications Of Sensor Arraysmentioning
confidence: 99%
See 1 more Smart Citation
“…119 Recently, an array-based CWA discrimination was realized based on organophosphorus-H 2 O 2 reaction-regulated chemiluminescence. 120 Disease Identification. Biomarkers are indicators that can determine the process of certain diseases, which are widely studied in clinical diagnosis and disease identification.…”
Section: ■ Applications Of Sensor Arraysmentioning
confidence: 99%
“…Subsequently, a colorimetric sensor array was proposed using iSense-proprietary 73-indicators as sensing units, achieving the identification of CWAs with an entirely automated workflow . Recently, an array-based CWA discrimination was realized based on organophosphorus-H 2 O 2 reaction-regulated chemiluminescence …”
Section: Applications Of Sensor Arraysmentioning
confidence: 99%
“…The Schoenemann method of detecting organophosphorus CWAs is still of interest today, as evidenced by some new proposals to optimize the reaction, such as a colourimetric method with the extraction of the reaction product into chloroform for application in field laboratories [16], increasing the reaction temperature [32], or the use of a chemiluminescence sensor system MgAl-LDH)-luminol-H2O2 (LDH = layer double hydrolysis) [33]. The Schoenemann method is relatively simple and can be used well in both laboratory and field conditions.…”
Section: Schoenemann Reactionmentioning
confidence: 99%
“…18 The second work by Zhang et al presented a chemiluminescence sensor array able to differentiate between OPCWAs based on a reaction with their phosphorus atom, however, in a relative manner. 19 In recent years, in parallel to the development of various uorescence-based probes, Shabat's group has put major efforts to establish an array of chemiluminescence sensors based on Schaap's dioxetane, 20 which are able to identify various analytes. [21][22][23][24] This sensitive technique seemed to be a highly potential new tool for OPCWA detection.…”
mentioning
confidence: 99%
“…18 The second work by Zhang et al presented a chemiluminescence sensor array able to differentiate between OPCWAs based on a reaction with their phosphorus atom, however, in a relative manner. 19…”
mentioning
confidence: 99%