Arsenic and its speciation in water samples by high performance liquid chromatography inductively coupled plasma mass spectrometry—Last decade review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
80
1

Year Published

2012
2012
2017
2017

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 132 publications
(83 citation statements)
references
References 56 publications
2
80
1
Order By: Relevance
“…At rst, the extraction according to Oliveira et al, also used by Sanchez-Rodas et al for PM 10 and by Sánchez de la Campa et al for PM 2.5 was evaluated. 12,14,15 The procedure consists of microwave extraction (150 W) of the lter during 4 min with 100 mM NH 2 OH-HCl.…”
Section: Performance Characteristics Of the Hplc/icp-ms Speciation Momentioning
confidence: 99%
See 1 more Smart Citation
“…At rst, the extraction according to Oliveira et al, also used by Sanchez-Rodas et al for PM 10 and by Sánchez de la Campa et al for PM 2.5 was evaluated. 12,14,15 The procedure consists of microwave extraction (150 W) of the lter during 4 min with 100 mM NH 2 OH-HCl.…”
Section: Performance Characteristics Of the Hplc/icp-ms Speciation Momentioning
confidence: 99%
“…8,9 For the determination of the individual species of arsenic, several combinations of techniques (separation + element-selective detection) have been attempted, but high-performance liquid chromatography (HPLC) in conjunction with ICP-MS or hydride generation atomic uorescence spectrometry (HG-AFS) has emerged as one of the best combinations for monitoring purposes. [1][2][3]6,7,[10][11][12][13][14][15][16][17][18][19][20][21][22][23] Most arsenic analytical techniques require samples to be extracted or digested prior to instrumental analysis. This approach was used consistently in the majority of the literature reviewed when particulate matter was collected on lter media.…”
Section: Introductionmentioning
confidence: 99%
“…Authors rarely give the value of the obtained LOQ and the manner of its designation. The most commonly employed method is to evaluate LOQ as 3 times the LOD [1]. In some papers, LOQ was calculated as 10 times the LOD, 6 or 10 times the standard deviation of the blank sample [24][25][26].…”
Section: Lod and Loqmentioning
confidence: 99%
“…The approach of hyphenating chromatographic methods to ICP-MS is a powerful tool for elemental speciation in environmental sciences [1]. The number of applications of HPLC-ICP-MS in speciation analysis is advancing, and the speciation of different biologically active compounds, including ions with different oxidation states, is a growing area of research [2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…A number of reviews focusing on the speciation analysis of these As species have been published in recent years [13][14][15][16][17]. Arsenosugars, a kind of As-containing carbohydrates, widely present in freshwater, marine biota and terrestrial organism.…”
Section: Speciation Of Asmentioning