2003
DOI: 10.1053/tvir.2003.36450
|View full text |Cite
|
Sign up to set email alerts
|

Arterial puncture closure using a collagen plug, II. (VasoSealTM)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0
1

Year Published

2006
2006
2011
2011

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 9 publications
0
6
0
1
Order By: Relevance
“…Since the first generation of the VasoSeal device was approved by the FDA in 1995, there have been a total of four different platforms of VasoSeal which include (1) VasoSeal Vascular Hemostasis Device (VHD), (2) VasoSeal ES (Extravascular Security), (3) VasoSeal Low Profile, and (4) VasoSeal Elite. 17,18 These various platforms are intended to be used for varying diameters of the arterial punctured site. Both VasoSeal Elite and ES utilize a temporary J-shaped locator segment, which is deployed so the collagen plug is deposited on the outer surface of the vessel wall along the puncture tract.…”
Section: Collagen-based Vascular Devicesmentioning
confidence: 99%
See 2 more Smart Citations
“…Since the first generation of the VasoSeal device was approved by the FDA in 1995, there have been a total of four different platforms of VasoSeal which include (1) VasoSeal Vascular Hemostasis Device (VHD), (2) VasoSeal ES (Extravascular Security), (3) VasoSeal Low Profile, and (4) VasoSeal Elite. 17,18 These various platforms are intended to be used for varying diameters of the arterial punctured site. Both VasoSeal Elite and ES utilize a temporary J-shaped locator segment, which is deployed so the collagen plug is deposited on the outer surface of the vessel wall along the puncture tract.…”
Section: Collagen-based Vascular Devicesmentioning
confidence: 99%
“…Numerous clinical series have reported high technical success rates ranging from 90% to 100%. 4,17,18,33,38,47 In patients who received systemic anticoagulation, this device remained efficacious in achieving hemostasis following percutaneous interventions. 17,47,48 Several comparative studies between the VasoSeal device and manual compression demonstrated no differences in the rate of femoral artery pseudoaneurysm or hematoma formation.…”
Section: Clinical Experience With Vascular Closure Devicesmentioning
confidence: 99%
See 1 more Smart Citation
“…If the device is applied at the end of the procedure, the patient can be mobilised immediately without serious complications or longer examination times [19]. At our unit, we have used this device for a few years now, with similar results to those described in the literature.…”
Section: Discussionmentioning
confidence: 61%
“…Esso, applicato al termine della procedura, consente un'immediata mobilizzazione del paziente senza significative complicanze né allungamento dei tempi necessari all'esecuzione dell'esame [19]. Nella nostra Unità Clinico Operativa viene utilizzato già da qualche anno tale dispositivo con risultati comparabili a quelli riscontrabili in letteratura.…”
Section: Discussionunclassified