2017
DOI: 10.1016/j.crad.2017.06.003
|View full text |Cite
|
Sign up to set email alerts
|

Arterial spin labelling MRI for detecting pseudocapsule defects and predicting renal capsule invasion in renal cell carcinoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…Synchronized breathing (e.g., [ 16 , 33 ]) arguably requires even higher levels of patient compliance. Respiratory-triggering using bellows allows scans to be performed under free-breathing [ 15 , 79 ], but lengthens the scan time and does not compensate for respiratory movement completely. Standard respiratory triggering implementations may require modifications (e.g., [ 55 ]) to cope with the time gap between trigger and data acquisition, particularly in multi-PLD protocols.…”
Section: Challengesmentioning
confidence: 99%
See 1 more Smart Citation
“…Synchronized breathing (e.g., [ 16 , 33 ]) arguably requires even higher levels of patient compliance. Respiratory-triggering using bellows allows scans to be performed under free-breathing [ 15 , 79 ], but lengthens the scan time and does not compensate for respiratory movement completely. Standard respiratory triggering implementations may require modifications (e.g., [ 55 ]) to cope with the time gap between trigger and data acquisition, particularly in multi-PLD protocols.…”
Section: Challengesmentioning
confidence: 99%
“…Signal averaging (used in the majority of renal ASL studies acquiring up to 100 control/label pairs [ 61 ], even though acquisitions with a range of 20–30 pairs are more common) suppresses artifacts, boosts perfusion-weighted SNR, and enables data rejection approaches (e.g., [ 27 ]) in the post-processing stage at the expense of additional scan time. Rejection of corrupted data can be performed by visual inspection of the data (e.g., [ 79 ]), or using automatic approaches, such as [ 58 , 80 , 81 , 82 ]. Image registration is particularly advantageous as it preserves SNR.…”
Section: Challengesmentioning
confidence: 99%
“…According to emerging research, innovative and more recent sequences, such as Arterial Spin Labelling, in combination with classical T2 sequences, could further improve the detection of PC invasion [20].…”
Section: Discussionmentioning
confidence: 99%
“…A recent magnetic resonance imaging (MRI) study showed that arterial spin labeling can be used to predict renal capsule invasion. [ 22 ] Other studies showed that the characterization of the renal capsule using MRI could reach 95% accuracy. [ 23 25 ] The present study suggests signs that could predict renal capsule invasion prior to initiating any treatment.…”
Section: Discussionmentioning
confidence: 99%