2021
DOI: 10.1111/ner.13341
|View full text |Cite
|
Sign up to set email alerts
|

Asleep Deep Brain Stimulation in Patients With Isolated Dystonia: Stereotactic Accuracy, Efficacy, and Safety

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 47 publications
1
8
0
Order By: Relevance
“…The clinical prognosis of patients with PD after DBS implantation is closely related to electrode implantation accuracy ( Chen et al, 2015 ; Li et al, 2016 ). Different anesthesia protocols involve different methods of ensuring that electrodes are implanted at the intended target ( Li et al, 2021 ). Intraoperative verification of the actual targets depended on MER and the stimulation test in the LA group and MER or intraoperative imaging in the GA group.…”
Section: Discussionmentioning
confidence: 99%
“…The clinical prognosis of patients with PD after DBS implantation is closely related to electrode implantation accuracy ( Chen et al, 2015 ; Li et al, 2016 ). Different anesthesia protocols involve different methods of ensuring that electrodes are implanted at the intended target ( Li et al, 2021 ). Intraoperative verification of the actual targets depended on MER and the stimulation test in the LA group and MER or intraoperative imaging in the GA group.…”
Section: Discussionmentioning
confidence: 99%
“…The downside to this approach is that accuracy becomes dependent uniquely on the frame system [56], in addition to the logistical difficulty of transporting patients between different locations. Alternatively, intraoperative CT images can be obtained and then fused to preoperative MRI to confirm lead placement [57][58][59], a procedure possibly limited by the accuracy of the image fusion software [58,60]. The use of interventional MRI-guided DBS using a skull-mounted aiming device in conjunction with dedicated software, which is independent of physiological testing, showed good accuracy and comparable outcomes in pediatric dystonia [29,61].…”
Section: Surgical Considerations In Pediatric Dbsmentioning
confidence: 99%
“…After the target and trajectory were planned, the DBS electrodes (Model 1210-40, SceneRay China or Model 3387S, Medtronic, USA) and the internal pulse generator (IPG, Model SR1101, SceneRay, or Model 37,612, Medtronic) were implanted under general anesthesia. CT scanning was performed immediately after lead implantation for all patients to exclude intracranial hemorrhage and fused to the preoperative MR images to confirm the electrode coordinates [ 24 ]. We performed staged surgery in the first two patients.…”
Section: Methodsmentioning
confidence: 99%