2015
DOI: 10.1016/j.foodres.2015.09.019
|View full text |Cite
|
Sign up to set email alerts
|

Assessing cocoa aroma quality by multiple analytical approaches

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
50
4
3

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 67 publications
(62 citation statements)
references
References 31 publications
5
50
4
3
Order By: Relevance
“…27,28 The procedure can be handled without any GC column (replaced by a short heated deactivated capillary) 26 or with a GC column used in isothermal conditions at 240°C to 250°C. 29,30 Alternatively, virtual fingerprints may be obtained by averaging 31 or summing 32 the mass spectra on a defined time of GC-MS measurements. As mass spectra are obtained by EI on low-resolution mass analysers, usually quadrupoles or sometimes ion-traps, 33 the resulting fingerprints are complex spectra of many overlapping fragments with unit resolution.…”
Section: Ms-based Electronic Nose-direct Injection Msmentioning
confidence: 99%
See 2 more Smart Citations
“…27,28 The procedure can be handled without any GC column (replaced by a short heated deactivated capillary) 26 or with a GC column used in isothermal conditions at 240°C to 250°C. 29,30 Alternatively, virtual fingerprints may be obtained by averaging 31 or summing 32 the mass spectra on a defined time of GC-MS measurements. As mass spectra are obtained by EI on low-resolution mass analysers, usually quadrupoles or sometimes ion-traps, 33 the resulting fingerprints are complex spectra of many overlapping fragments with unit resolution.…”
Section: Ms-based Electronic Nose-direct Injection Msmentioning
confidence: 99%
“…Dynamic HS sampling can be replaced by SPME, as exemplified for off‐flavours in milks and rapid characterization of cheeses . This method is referred to as “MS‐based electronic nose” or “MS‐based e‐nose.” The procedure can be handled without any GC column (replaced by a short heated deactivated capillary) or with a GC column used in isothermal conditions at 240°C to 250°C . Alternatively, virtual fingerprints may be obtained by averaging or summing the mass spectra on a defined time of GC‐MS measurements.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A NIR spectroscopy-electronic tongue integrated approach was accurately used for classifying cocoa bean varieties [10,11]. Other researchers showed that Mass Spectrometry (MS)fingerprinting could be a reliable and fast method for predicting the aroma potential and quality of roasted cocoa beans, the extent of processing as well as their geographical origin [12]. The influence of the roasting process conditions on the polyphenol contents of cocoa beans, nibs and chocolates have been evaluated by UPLC-DAD-ESI-MS/MS [13].…”
Section: Introductionmentioning
confidence: 99%
“…A classification chemometric model based on HR-MS 1H NMR data has been also proposed for assessing the geographical origin of cocoa beans [19]. Finally, cocoa fermentation quality and aroma formation potential have been evaluated by gas chromatography-mass spectrometry (GC-MS) [12], [20]. Indeed, advanced chemical untargeted and targeted fingerprinting together with twodimensional GC-MS may be used as a pattern recognition tool for classification, discrimination, and sensory-quality assessment of high-quality cocoa at early processing stages [21].…”
Section: Introductionmentioning
confidence: 99%