Assessing the Effectiveness of Surface Cleaning Methods in Intravitreal Injection Procedure Rooms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 28 publications
0
8
0
Order By: Relevance
“…We defined RLU thresholds, based on literature review and on previous ATP measurements in the participating hospitals before the project started [8]. Other studies have recommended an RLU threshold for cleanliness at 250-500 RLU, however this threshold is intended for measurement (almost) directly after cleaning [4,6,8,[14][15][16]. We developed ATP thresholds for conducting an ATP measurement at a random point in time on a hospital ward, not knowing if items were used or cleaned that day.…”
Section: Discussionmentioning
confidence: 99%
“…We defined RLU thresholds, based on literature review and on previous ATP measurements in the participating hospitals before the project started [8]. Other studies have recommended an RLU threshold for cleanliness at 250-500 RLU, however this threshold is intended for measurement (almost) directly after cleaning [4,6,8,[14][15][16]. We developed ATP thresholds for conducting an ATP measurement at a random point in time on a hospital ward, not knowing if items were used or cleaned that day.…”
Section: Discussionmentioning
confidence: 99%
“…13 Other studies have recommended an RLU threshold for cleanliness at 250-500 RLU, however this threshold is intended for measurement (almost) directly after cleaning. 4,6,8,14,15,16 We developed ATP thresholds for conducting an ATP measurement at a random point in time on a hospital ward, not knowing if items were used or cleaned that day. The goal of this study was to visualize the environmental contamination independent from the time of cleaning and to determine the environmental contamination to which a patient is exposed in the hospital.…”
Section: Discussionmentioning
confidence: 99%
“…8 Other studies have recommended an RLU threshold for cleanliness at 250-500 RLU, however this threshold is intended for measurement (almost) directly after cleaning. 4,6,8,14,15,16 We developed ATP thresholds for conducting an ATP measurement at a random point in time on a hospital ward, not knowing if items were used or cleaned that day. The goal of this study was to visualize the environmental contamination independent from the time of cleaning and to determine the environmental contamination to which a patient is exposed in the hospital.…”
Section: Discussionmentioning